Literature DB >> 10231845

11C-methionine uptake to the pancreas and its secretion: a positron emission tomography study in humans.

A Takasu1, T Shimosegawa, E Shimosegawa, J Hatazawa, K Kimura, M Fujita, M Koizumi, I Kanno, T Toyota.   

Abstract

The aim of this study was to investigate the uptake of [11C-methyl]-L-methionine (11C-methionine) in the human pancreas by analyzing dynamic positron emission tomography (PET) images and the duodenal aspirate. A double-lumen tube was inserted in the duodenum and dynamic PET was performed in seven healthy volunteers for 110 min after intravenous (i.v.) injection of 11C-methionine during the continuous i.v. administration of secretin (125 ng/kg/h) and cerulein (30 ng/kg/h). For the calculation of the radioactivity in the pancreas, the regions of interest were set on the PET images. Radioactivity was measured in 10-min fractions of duodenal juice. After i.v. injection, 11C-methionine accumulated in the pancreas within a few minutes, and the radioactivity plateaued during the study. The radiolabeled proteins in the duodenal juice increased linearly 30 min after 11C-methionine injection, but the relative rates of radioactivity in the protein precipitate to the total count in the duodenal juice were 44-48%. From these findings, it was concluded that 11C-methionine accumulation in the pancreas is very rapid after the i.v. administration, and only a part of methionine uptake to the pancreas is incorporated into secretory proteins. The pancreatic 11C-methionine uptake detected by PET may represent a new aspect of exocrine pancreatic function that has not been expressed by the conventional intubation method.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10231845     DOI: 10.1097/00006676-199905000-00010

Source DB:  PubMed          Journal:  Pancreas        ISSN: 0885-3177            Impact factor:   3.327


  4 in total

1.  Hepatic metabolism of 11C-methionine and secretion of 11C-protein measured by PET in pigs.

Authors:  Jacob Horsager; Susanne Bach Lausten; Dirk Bender; Ole Lajord Munk; Susanne Keiding
Journal:  Am J Nucl Med Mol Imaging       Date:  2017-09-01

Review 2.  Variants and Pitfalls in PET/CT Imaging of Gastrointestinal Cancers.

Authors:  Vetri Sudar Jayaprakasam; Viktoriya Paroder; Heiko Schöder
Journal:  Semin Nucl Med       Date:  2021-05-06       Impact factor: 4.802

3.  **-Postprandial pancreatic [11C]methionine uptake after pancreaticoduodenectomy mirrors basal beta cell function and insulin release.

Authors:  Emanuel Steiner; Lukas Kazianka; Robert Breuer; Marcus Hacker; Wolfgang Wadsak; Markus Mitterhauser; Thomas Stimpfl; Birgit Reiter; Georgios Karanikas; Johannes Miholic
Journal:  Eur J Nucl Med Mol Imaging       Date:  2016-07-07       Impact factor: 9.236

4.  Optimization of [11C]methionine PET study: appropriate scan timing and effect of plasma amino acid concentrations on the SUV.

Authors:  Kayako Isohashi; Eku Shimosegawa; Hiroki Kato; Yasukazu Kanai; Sadahiro Naka; Koichi Fujino; Hiroshi Watabe; Jun Hatazawa
Journal:  EJNMMI Res       Date:  2013-04-15       Impact factor: 3.138

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.