Literature DB >> 10231460

Assessing dialysis adequacy and dietary intake in the individual hemodialysis patient.

W D Kloppenburg1, C A Stegeman, M Hooyschuur, J van der Ven, P E de Jong, R M Huisman.   

Abstract

BACKGROUND: Urea kinetic modeling (UKM) and food records are widely used to assess the dialysis adequacy. Clinicians use these methods in individual patients to decide whether the dialysis prescription should be adjusted. We determined the variation in UKM parameters and dietary intake within individual patients in order to determine the required number of UKM measurements, and the number of food recording days to assess dialysis adequacy and dietary intake reliably.
METHODS: Session-to-session variation in urea reduction ratio (URR), Kt/V, urea distribution volume (UDVDDQ), and protein catabolic rate (PCR) was determined during three mid-week dialysis sessions in 50 stable hemodialysis patients on three-times per week hemodialysis with a Kt/V of 0.98 +/- 0.13 (mean +/- SD). The dialysis prescription was kept constant. The day-to-day variation in dietary protein intake (DPI) and dietary energy intake (DEI) was determined from seven-day food records. The 90th percentile value of the coefficient of variation (CV) was used to determine the number of measurements.
RESULTS: The variation in URR [CV, 2.4% (0.3 to 9.5) median (range)] and in Kt/V [CV, 4.0% (0.6 to 11.6)] was small in the majority of the patients. The variation in UDVDDQ [CV, 4.9% (0.3 to 25.7)] and PCR [CV, 9.3% (0.8 to 28.5)] was considerably larger. The variation in DPI [CV, 17.3% (8.4 to 64.0)] was larger than that in DEI [CV, 12.9% (5.0 to 33.0)]. To assess the URR within +/- 10% of its true value, the average of two measurements was required. Reliable assessment of Kt/V required three measurements. URR and Kt/V could be assessed reliably from a single measurement in 86 and 66% of the patients, but we were not able to distinguish these patients beforehand. Reliable estimation of UDVDDQ required six measurements. The required number of measurements for PCR, DPI, and DEI was determined using a precision of +/- 20%. To assess PCR reliably, three measurements were needed. Estimation of DPI and DEI required seven and five food recording days, respectively.
CONCLUSIONS: The session-to-session variation in URR and Kt/V is small in stable hemodialysis patients. Nevertheless, the averaged value of two to three measurements is required to assess the dose of dialysis reliably. Assessment of dietary intake requires at least three PCR measurements or food records for at least one week. Basing clinical decisions on a single dialysis adequacy assessment is an unjustified practice that should be abandoned.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10231460     DOI: 10.1046/j.1523-1755.1999.00412.x

Source DB:  PubMed          Journal:  Kidney Int        ISSN: 0085-2538            Impact factor:   10.612


  11 in total

Review 1.  Dietary assessment of individuals with chronic kidney disease.

Authors:  Rachelle Bross; Nazanin Noori; Csaba P Kovesdy; Sameer B Murali; Debbie Benner; Gladys Block; Joel D Kopple; Kamyar Kalantar-Zadeh
Journal:  Semin Dial       Date:  2010-07-29       Impact factor: 3.455

2.  Association of dietary phosphorus intake and phosphorus to protein ratio with mortality in hemodialysis patients.

Authors:  Nazanin Noori; Kamyar Kalantar-Zadeh; Csaba P Kovesdy; Rachelle Bross; Debbie Benner; Joel D Kopple
Journal:  Clin J Am Soc Nephrol       Date:  2010-02-25       Impact factor: 8.237

3.  Dietary potassium intake and mortality in long-term hemodialysis patients.

Authors:  Nazanin Noori; Kamyar Kalantar-Zadeh; Csaba P Kovesdy; Sameer B Murali; Rachelle Bross; Allen R Nissenson; Joel D Kopple
Journal:  Am J Kidney Dis       Date:  2010-06-30       Impact factor: 8.860

4.  Nutrition parameters as hemodialysis adequacy markers.

Authors:  R Stolic; G Trajkovic; D Stolic; V Peric; G Subaric-Gorgieva
Journal:  Hippokratia       Date:  2010-07       Impact factor: 0.471

Review 5.  An update on nutrition in chronic kidney disease.

Authors:  Denis Fouque; Fitsum Guebre-Egziabher
Journal:  Int Urol Nephrol       Date:  2006-11-24       Impact factor: 2.266

6.  Online conductivity monitoring of dialysis adequacy versus Kt/V derived from urea reduction ratio: A prospective study from a Saudi center.

Authors:  Khalid Al Saran; Alaa Sabry; Mamdouh Abdulghafour; Ahmed Yehia
Journal:  Int J Nephrol Renovasc Dis       Date:  2009-10-09

7.  Factors associated with quality of life among hemodialysis patients in Malaysia.

Authors:  Nor Baizura Md Yusop; Chan Yoke Mun; Zalilah Mohd Shariff; Choo Beng Huat
Journal:  PLoS One       Date:  2013-12-16       Impact factor: 3.240

8.  Association of Extreme Heat Events With Hospital Admission or Mortality Among Patients With End-Stage Renal Disease.

Authors:  Richard V Remigio; Chengsheng Jiang; Jochen Raimann; Peter Kotanko; Len Usvyat; Frank W Maddux; Patrick Kinney; Amir Sapkota
Journal:  JAMA Netw Open       Date:  2019-08-02

9.  A review article: access recirculation among end stage renal disease patients undergoing maintenance hemodialysis.

Authors:  Abbasali Zeraati; Seyed Seifollah Beladi Mousavi; Marzieh Beladi Mousavi
Journal:  Nephrourol Mon       Date:  2013-03-30

10.  Does the adequacy parameter Kt/V(urea) reflect uremic toxin concentrations in hemodialysis patients?

Authors:  Sunny Eloot; Wim Van Biesen; Griet Glorieux; Nathalie Neirynck; Annemieke Dhondt; Raymond Vanholder
Journal:  PLoS One       Date:  2013-11-13       Impact factor: 3.240