Literature DB >> 10231189

In vivo relaxation times of gray matter and white matter in spinal cord.

P Narayana1, D Fenyes, N Zacharopoulos.   

Abstract

In vivo relaxation times and relative spin densities of gray matter (GM) and white matter (WM) of rat spinal cord were measured. Inductively coupled implanted RF coil was used to improve the signal-to-noise ratio required for making these measurements. The estimated relaxation times (in milliseconds) are: T1(GM) = 1021+/-93, T2(GM) = 64+/-3.4, T1(WM) = 1089+/-126, and T2(WM) = 79+/-6.9. The estimated relative spin densities are: rho(GM) = (60+/-2.3)% and rho(WM) = (40+/-2.1)%. The T1 values of GM and white matter are not statistically different. However, the differences in T2 values and spin densities of GM and WM are statistically significant. These in vivo measurements indicate that the observed contrast between GM and WM in spinal cord MR images mainly arises from the differences in the spin density.

Entities:  

Mesh:

Year:  1999        PMID: 10231189     DOI: 10.1016/s0730-725x(98)00194-5

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  8 in total

1.  Characterization of late radiation effects in the rat thoracolumbar spinal cord by MR imaging using USPIO.

Authors:  M E P Philippens; G Gambarota; J A Pikkemaat; W J M Peeters; A J van der Kogel; A Heerschap
Journal:  MAGMA       Date:  2004-12-21       Impact factor: 2.310

2.  Development of an inductively coupled MR coil system for imaging and spectroscopic analysis of an implantable bioartificial construct at 11.1 T.

Authors:  Nelly A Volland; Thomas H Mareci; Ioannis Constantinidis; Nicholas E Simpson
Journal:  Magn Reson Med       Date:  2010-04       Impact factor: 4.668

3.  In vivo contrast-enhanced MR imaging of direct infusion into rat peripheral nerves.

Authors:  Xiaoming Chen; Garrett W Astary; Thomas H Mareci; Malisa Sarntinoranont
Journal:  Ann Biomed Eng       Date:  2011-08-02       Impact factor: 3.934

4.  High-resolution MR imaging of the rat spinal cord in vivo in a wide-bore magnet at 17.6 Tesla.

Authors:  V C Behr; T Weber; T Neuberger; M Vroemen; N Weidner; U Bogdahn; A Haase; P M Jakob; C Faber
Journal:  MAGMA       Date:  2004-10-23       Impact factor: 2.310

5.  Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

Authors:  Xiaoliang Zhang; Xiao-Hong Zhu; Runxia Tian; Yi Zhang; Hellmut Merkle; Wei Chen
Journal:  MAGMA       Date:  2003-07-04       Impact factor: 2.310

6.  Voxelized model of interstitial transport in the rat spinal cord following direct infusion into white matter.

Authors:  Jung Hwan Kim; Garrett W Astary; Xiaoming Chen; Thomas H Mareci; Malisa Sarntinoranont
Journal:  J Biomech Eng       Date:  2009-07       Impact factor: 2.097

7.  Comprehensive small animal imaging strategies on a clinical 3 T dedicated head MR-scanner; adapted methods and sequence protocols in CNS pathologies.

Authors:  Deepu R Pillai; Robin M Heidemann; Praveen Kumar; Nagesh Shanbhag; Titus Lanz; Michael S Dittmar; Beatrice Sandner; Christoph P Beier; Norbert Weidner; Mark W Greenlee; Gerhard Schuierer; Ulrich Bogdahn; Felix Schlachetzki
Journal:  PLoS One       Date:  2011-02-07       Impact factor: 3.240

8.  In-vivo multi-exponential T2, magnetization transfer and quantitative histology in a rat model of intramyelinic edema.

Authors:  Kevin D Harkins; William M Valentine; Daniel F Gochberg; Mark D Does
Journal:  Neuroimage Clin       Date:  2013-06-22       Impact factor: 4.881

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.