This investigation documented the locations of endoscopically applied T-Fix suture devices (Acufex Microsurgical, Mansfield, MA) placed in six fresh-frozen cadaveric knees (age, 60 to 72 years) in relationship to the joint capsule, and adjacent neurovascular and musculotendinous structures. Five T-Fix devices were placed in the posterior meniscal regions at approximately 20 degree intervals. Gross dissection enabled T-Fix bar and suture placement identification. Fifty total devices were placed (23 medially and 27 laterally). Lateral: None of the devices penetrated more superficially than the deepest capsular layer (layer III). Six of the 27 devices placed at the posterior horn of the lateral meniscus pierced the popliteus tendon. None of the bars pierced the lateral collateral ligament (layer III). All devices placed at the posterolateral knee were outside the arcuate ligament (layer III) but inside the fabellofibular ligament (layer II). Medial: Seven of the 23 devices pierced the deep medial collateral ligament (MCL, layer III), and 4 pierced the superficial MCL (layer II). Three devices pierced the sartorius tendon (layer I) and one pierced the gracilis tendon (layer II). None of the medial devices created a plicating effect on the posterior capsule. None of the devices were placed near neurovascular structures. Devices placed within the posterior meniscal horns had a > or =1.5-cm buffer zone from the popliteal neurovascular bundle. Most bars (36 of 50) were anchored to the capsular layer (layer III) after piercing the meniscocapsular junction (layer II). T-Fix devices simulating arthroscopic all-inside meniscal repair provided well-positioned, solid suture anchorage through the junction with no neurovascular involvement. Care needs to be taken when placing lateral (popliteus muscle) and medial (gracilis, sartorius tendons and superficial MCL) devices to avoid possible soft tissue tenodesis.

Entities:  

Mesh:

Year:  1999        PMID: 10231105     DOI: 10.1016/s0749-8063(99)70034-4

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  2 in total

1.  Determination of the safe penetration depth during all-inside meniscal repair of the posterior part of the lateral meniscus using the FasT-Fix suture repair system.

Authors:  Mohamed Mahmoud Abouheif; Hayatoshi Shibuya; Takuya Niimoto; Wirat Kongcharoensombat; Masataka Deie; Nobuo Adachi; Mitsuo Ochi
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2011-04-06       Impact factor: 4.342

2.  Biomechanical Comparison of Parallel and Crossed Suture Repair for Longitudinal Meniscus Tears.

Authors:  Charles Milchteim; Eric A Branch; Ty Maughon; Jay Hughey; Adam W Anz
Journal:  Orthop J Sports Med       Date:  2016-04-08
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.