Literature DB >> 10228521

Splanchnic arterial stenosis or occlusion: diagnosis at Doppler US.

H K Lim1, W J Lee, S H Kim, S J Lee, S H Choi, H S Park, Y S Do, S W Choo, I W Choo.   

Abstract

PURPOSE: To determine the diagnostic accuracy of Doppler ultrasonography (US) in the detection of high-grade stenosis or occlusion of the celiac artery (CA) and superior mesenteric artery (SMA) and validate the previously reported Doppler US criteria.
MATERIALS AND METHODS: During a recent 36-month period, 82 patients were prospectively examined with Doppler US of the splanchnic arteries and with lateral abdominal aortography, regardless of their abdominal symptoms. The previously reported diagnostic criteria with the fasting peak systolic velocity measurement were prospectively used in all patients. The results of Doppler US were compared with those of lateral aortography.
RESULTS: The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of Doppler US for the detection of 70% or greater CA stenosis or occlusion were 100%, 87%, 57%, 100%, and 89%, respectively; for 70% or greater SMA stenosis or occlusion, these values were 100%, 98%, 93%, 100%, and 99%, respectively.
CONCLUSION: Owing to its high accuracy in the diagnosis of high-grade splanchnic arterial stenosis or occlusion, Doppler US can be used as a screening method to help detect CA or SMA stenosis or occlusion and can reduce the use of unnecessary, invasive angiography.

Entities:  

Mesh:

Year:  1999        PMID: 10228521     DOI: 10.1148/radiology.211.2.r99ma27405

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  3 in total

1.  Increased splanchnic arterial vascular resistance in oldest old patients - possible relevance for postprandial hypotension.

Authors:  S Wicklein; W Mühlberg; B Richter; C C Sieber
Journal:  Z Gerontol Geriatr       Date:  2007-02       Impact factor: 1.281

2.  A variant of the median arcuate ligament syndrome: are sagittal images enough for diagnosis?

Authors:  Muzaffer Saglam; Huseyin Onur Sildiroglu; Mehmet Incedayi; Kemal Kara; Hasan Saygin
Journal:  Wien Klin Wochenschr       Date:  2013-04-20       Impact factor: 1.704

3.  Ultrasound of living donor liver transplantation.

Authors:  L Leong
Journal:  Biomed Imaging Interv J       Date:  2006-04-01
  3 in total