Modeling of polychromatic attenuation using computed tomography reconstructed images.

C H Yan1, R T Whalen, G S Beaupré, S Y Yen, S Napel.   

Abstract

This paper presents a procedure for estimating an accurate model of the CT imaging process including spectral effects. As raw projection data are typically unavailable to the end-user, we adopt a post-processing approach that utilizes the reconstructed images themselves. This approach includes errors from x-ray scatter and the nonidealities of the built-in soft tissue correction into the beam characteristics, which is crucial to beam hardening correction algorithms that are designed to be applied directly to CT reconstructed images. We formulate this approach as a quadratic programming problem and propose two different methods, dimension reduction and regularization, to overcome ill conditioning in the model. For the regularization method we use a statistical procedure, Cross Validation, to select the regularization parameter. We have constructed step-wedge phantoms to estimate the effective beam spectrum of a GE CT-I scanner. Using the derived spectrum, we computed the attenuation ratios for the wedge phantoms and found that the worst case modeling error is less than 3% of the corresponding attenuation ratio. We have also built two test (hybrid) phantoms to evaluate the effective spectrum. Based on these test phantoms, we have shown that the effective beam spectrum provides an accurate model for the CT imaging process. Last, we used a simple beam hardening correction experiment to demonstrate the effectiveness of the estimated beam profile for removing beam hardening artifacts. We hope that this estimation procedure will encourage more independent research on beam hardening corrections and will lead to the development of application-specific beam hardening correction algorithms.

Keywords:  NASA Center ARC; NASA Discipline Musculoskeletal

Mesh:

Substances:

Year:  1999        PMID: 10227366     DOI: 10.1118/1.598563

Source DB:  PubMed          Journal:  Med Phys        ISSN: 0094-2405            Impact factor:   4.071


  3 in total

1.  Dual-Energy Technique at Low Tube Voltages for Small Animal Imaging.

Authors:  Seungryong Cho; Emil Y Sidky; Junguo Bian; Xiaochuan Pan
Journal:  Tsinghua Sci Technol       Date:  2010-02       Impact factor: 2.016

2.  Specimen size and porosity can introduce error into microCT-based tissue mineral density measurements.

Authors:  Roberto J Fajardo; Esther Cory; Nipun D Patel; Ara Nazarian; Andres Laib; Rajaram K Manoharan; James E Schmitz; Jeremy M DeSilva; Laura M MacLatchy; Brian D Snyder; Mary L Bouxsein
Journal:  Bone       Date:  2008-09-10       Impact factor: 4.398

3.  Narrow-Energy-Width CT Based on Multivoltage X-Ray Image Decomposition.

Authors:  Jiaotong Wei; Yan Han; Ping Chen
Journal:  Int J Biomed Imaging       Date:  2017-11-07
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.