Literature DB >> 10225080

Effects of a leucocyte depleting arterial line filter on perioperative proteolytic enzyme and oxygen free radical release in patients undergoing aortocoronary bypass surgery.

P Mair1, C Hoermann, J Mair, J Margreiter, B Puschendorf, D Balogh.   

Abstract

BACKGROUND: Proteolytic enzymes and oxygen free radicals released from activated leucocytes contribute significantly to the organ dysfunction associated with cardiopulmonary bypass. Leucocyte depletion during extracorporeal circulation should reduce the release of these toxic compounds and thereby improve postbypass myocardial and pulmonary function. Recently, a leucocyte-specific arterial line filter to achieve leucocyte depletion during clinical perfusion has become commercially available. The aim of this study, therefore, was to evaluate the influence of the leucocyte depleting arterial line filter on proteolytic enzyme release, oxygen free radical release and postbypass pulmonary and myocardial function in patients undergoing bypass surgery.
METHODS: Forty patients undergoing elective aortocoronary bypass surgery were included into this prospective, randomized clinical study, 20 in the leucocyte depletion (LG-6 group, leucocyte-specific arterial line filter) and 20 in the control group (AV-6 group, standard arterial line filter). White cell count, differential white cell count, plasma elastase concentration, plasma malondialdehyde concentration and C-reactive protein were determined before, twice during and immediately after cardiopulmonary bypass, at the end of surgery and 6 and 20 h thereafter.
RESULTS: White cell count, differential white cell count, malondialdehyde and C-reactive protein were not significantly different between LG-6 and control patients. Plasma elastase concentrations were significantly (P < or = 0.03) higher during and immediately after extracorporeal circulation in LG-6 group patients. Need for inotropic support, arterial pO2 after extracorporeal circulation and perioperative CK MB mass and troponin I release were not different between the two groups of patients.
CONCLUSION: The use of a leucocyte depleting arterial line filter is associated with an increased release of the proteolytic enzyme elastase, but does not reliably and consistently achieve effective leucocyte depletion during clinical perfusion. In contrast to previous studies, we could not demonstrate any significant difference in postbypass pulmonary or myocardial function between patients perfused with the leucocyte-specific arterial line filter and control patients. Our data do not support the routine use of a leucocyte depleting arterial line filter during clinical perfusion in patients undergoing elective aortocoronary bypass surgery.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10225080     DOI: 10.1034/j.1399-6576.1999.430414.x

Source DB:  PubMed          Journal:  Acta Anaesthesiol Scand        ISSN: 0001-5172            Impact factor:   2.105


  2 in total

Review 1.  From trash to leucocytes: what are we filtering and why?

Authors:  Simon J Mitchell
Journal:  J Extra Corpor Technol       Date:  2006-03

Review 2.  Use of leukocyte-depleting filters during cardiac surgery with cardiopulmonary bypass: a review.

Authors:  Shalini Boodram; Ed Evans
Journal:  J Extra Corpor Technol       Date:  2008-03
  2 in total