Literature DB >> 10221071

Chromatographic detection using tris(2,2'-bipyridyl)ruthenium(III) as a fluorogenic electron-transfer reagent.

S J Woltman1, W R Even, S G Weber.   

Abstract

Tris(2,2'-bipyridyl)ruthenium can be excited to fluorescence by visible light (lambda abs 454 nm, lambda em 607 nm) when in the M(II) oxidation state, but not in the M(III) state. A novel chromatographic detection method using the non-fluorescent M(III) form of the complex as a postcolumn fluorogenic reagent is demonstrated. The M(III) form is a powerful oxidizing agent (E degree = 1.27 V vs NHE, 1.05 V vs Ag/AgCl). The M(III) reagent is generated on-line from the M(II) form of the complex by a highly efficient porous carbon electrode and then reacted briefly with chromatographic effluent; the M(II) created by electron transfer from oxidation-susceptible analytes is then detected by fluorescence. The fluorescence detector can be calibrated for number of electrons transferred by injection of either M(II) or an oxidative standard such as ferrocyanide. It is hoped that this redox-based detection scheme will provide an alternative to electrochemical detection. Among the advantages are freedom from surface fouling and the potential for extremely low detection limits. The scheme was applied to detection of the peptide dynorphin A and several of its fragments. Dynorphin A contains tyrosine at the N-terminus (position 1) and tryptophan in position 15; these amino acid residues are susceptible to oxidation and peptides containing them can be detected on that basis. Flow injection testing of the model compounds Tyr-Gly-Gly-Phe-Leu and Gly-Gly-Trp-Gly indicated that tyrosine transferred approximately 1 electron to the M(III) reagent and that tryptophan transferred approximately 4 electrons. Similar results were obtained from the chromatographic runs. Dynorphin A and six dynorphin A fragments containing the N-terminal tyrosine were detected easily at 100 nM concentration (14 pmol) using laser-induced fluorescence. As expected, one fragment that did not contain tryptophan or tyrosine was not detected. A mass detection limit of 80 fmol was estimated for the tyrosine-containing fragments.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10221071     DOI: 10.1021/ac981181e

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  4 in total

1.  Techniques for neuropeptide determination.

Authors:  Mats Sandberg; Stephen G Weber
Journal:  Trends Analyt Chem       Date:  2003-09       Impact factor: 12.296

2.  Use of tris(2,2'-bipyridine)osmium as a photoluminescence-following electron-transfer reagent for postcolumn detection in capillary high-performance liquid chromatography.

Authors:  Moon Chul Jung; Nicole Munro; Guoyue Shi; Adrian C Michael; Stephen G Weber
Journal:  Anal Chem       Date:  2006-03-15       Impact factor: 6.986

3.  Influence of chemical kinetics on postcolumn reaction in a capillary Taylor reactor with catechol analytes and photoluminescence following electron transfer.

Authors:  Moon Chul Jung; Stephen G Weber
Journal:  Anal Chem       Date:  2005-02-15       Impact factor: 6.986

4.  Simultaneous determination of biogenic monoamines in rat brain dialysates using capillary high-performance liquid chromatography with photoluminescence following electron transfer.

Authors:  Moon Chul Jung; Guoyue Shi; Laura Borland; Adrian C Michael; Stephen G Weber
Journal:  Anal Chem       Date:  2006-03-15       Impact factor: 6.986

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.