A novel vascular sealing device for closure of percutaneous arterial access sites.

S Silber1, G Gershony, B Schön, N Schön, T Jensen, W Schramm.   

Abstract

The purpose of this study was to investigate the safety and efficacy of a novel vascular sealing device that incorporates a unique low-profile balloon-positioning catheter and a procoagulant delivered after diagnostic cardiac catheterization and percutaneous transluminal coronary angioplasty (PTCA) procedures. Current management of the vascular access site after percutaneous interventions is associated with patient discomfort and complications. Based on previously reported successful results in canine models, we proceeded with this first human feasibility and safety study. Immediately after an invasive procedure, the sealing device was successfully deployed at the femoral arterial access site in 24 of 24 procedures (diagnostic 19, PTCA 5). All patients were followed up at 1 month with clinical assessment, ankle-brachial index measurement, and Doppler ultrasound. Successful hemostasis was achieved in all patients. The activated clotting time before sealing device deployment was 125.5 +/- 22.2 and 267.8 +/- 60.0 seconds for diagnostic and PTCA patients, respectively. The time to hemostasis was 2.5 +/- 0.9 minutes for diagnostic and 6.0 +/- 2.2 minutes for PTCA patients. No major complications were observed. Coagulation markers (fibrinogen, D-dimer, thrombin-antithrombin-3 complex, and prothrombin fragment 1 and 2) measured before and after sealing device deployment did not reveal excessive intravascular thrombin generation or other coagulopathy. This novel vascular sealing device successfully achieves safe and effective vascular access site hemostasis immediately after cardiac catheterization and PTCA. These promising first human results will need to be confirmed by a multicenter randomized trial.

Entities:  

Mesh:

Year:  1999        PMID: 10215293     DOI: 10.1016/s0002-9149(99)00067-3

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Final report of the European multi-center registry using the Duett vascular sealing device.

Authors:  S Silber; A J Tofte; T O Kjellevand; E Grube; G Gershony
Journal:  Herz       Date:  1999-12       Impact factor: 1.443

2.  Access-site complications after rescue percutaneous coronary intervention during thrombolysis for acute myocardial infarction.

Authors:  A Germing; M Lindstaedt; S Ulrich; W Bojara; T Lawo; A Mügge; P Grewe
Journal:  Z Kardiol       Date:  2005-01

3.  Large femoral aneurysm as a late complication after vessel closure device application.

Authors:  Alfried Germing; Peter Grewe; Andreas Mügge; Michael Lindstaedt
Journal:  Clin Res Cardiol       Date:  2006-04-03       Impact factor: 5.460

4.  Randomized comparison of effects of suture-based and collagen-based vascular closure devices on post-procedural leg perfusion.

Authors:  H I M Kälsch; H Eggebrecht; S Mayringer; T Konorza; B Sievers; S Sack; R Erbel; K Kroeger
Journal:  Clin Res Cardiol       Date:  2007-09-18       Impact factor: 5.460

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.