Evaluation of absolute cerebral blood flow by laser-Doppler scanning-- comparison with hydrogen clearance.

R Uranishi1, H Nakase, T Sakaki, O S Kempski.   

Abstract

A major limitation of laser-Doppler (LD) flowmetry, which enables noninvasive and continuous recording of tissue perfusion, is its inability to evaluate the absolute cerebral blood flow (CBF). Using a computer-controlled micromanipulator, the LD scanning technique provides information on the brain microcirculation in many different locations, information which is not available from a single stationary probe. The purpose of the current study was to examine whether LD scanning estimates can be calibrated for the absolute CBF by comparing LD scanning with the hydrogen clearance (HC) method. In Wistar rats (n = 31) including old rats (122-123 weeks old, n = 8), the CBF was altered using the global ischemia model by bilateral carotid artery occlusion coupled with hypobaric hypotension. The CBF was determined simultaneously by the LD scanning technique and HC at each mean arterial blood pressure step, and the correlation of CBF between the two techniques was analyzed. CBF measured by LD scanning was expressed as LD units. Absolute CBF values obtained by methods were correlated (r = 0.87), and the formula to calibrate absolute CBF values from LD units was y = 1.8x - 0.6. On the other hand, in old rats the formula to calibrate the absolute values was different (y = 1.3x + 8.3, r = 0.85). The results suggest that CBF data obtained by LD scanning could be calibrated into absolute blood flow values in particular circumstances, and that LD scanning could compensate in part for the weakness of LD flowmetry.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10213904     DOI: 10.1159/000025631

Source DB:  PubMed          Journal:  J Vasc Res        ISSN: 1018-1172            Impact factor:   1.934


  3 in total

1.  A scalable correlator for multichannel diffuse correlation spectroscopy.

Authors:  Christopher J Stapels; Noah J Kolodziejski; Daniel McAdams; Matthew J Podolsky; Daniel E Fernandez; Dana Farkas; James F Christian
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-07

2.  Spatiotemporal image correlation spectroscopy measurements of flow demonstrated in microfluidic channels.

Authors:  Molly Rossow; William W Mantulin; Enrico Gratton
Journal:  J Biomed Opt       Date:  2009 Mar-Apr       Impact factor: 3.170

3.  Laser doppler blood flow imaging using a CMOS imaging sensor with on-chip signal processing.

Authors:  Diwei He; Hoang C Nguyen; Barrie R Hayes-Gill; Yiqun Zhu; John A Crowe; Cally Gill; Geraldine F Clough; Stephen P Morgan
Journal:  Sensors (Basel)       Date:  2013-09-18       Impact factor: 3.576

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.