AIMS: To examine body composition in preterm infants. METHODS: Body composition was measured by dual energy x-ray absorptiometry (DEXA) at hospital discharge, term, 12 weeks, and at 6 and 12 months corrected age in 125 infants (birthweight < or = 1750 g, gestational age < or = 34 weeks). RESULTS: Body weight derived by DEXA accurately predicted that determined by conventional scales. In both sexes lean mass (LM), fat mass (FM), %FM, bone area (BA), bone mineral mass (BMM), and bone mineral density (BMD) increased rapidly during the study; significant changes were detectable between discharge and term. At 12 months, LM, BA, and BMM, but not FM, %FM, or BMD were greater in boys than in girls. Corrected for age, LM was less than those of the reference term infant; FM and %FM were similar; BMM was greater. Corrected for weight, LM was similar to those of the reference infant, while the FM and %FM of study infants were slightly greater. CONCLUSIONS: DEXA accurately measures body mass. Body composition in preterm boys and girls differs. Interpretation of DEXA values may depend on whether age or body weight are regarded as the appropriate reference.
AIMS: To examine body composition in preterm infants. METHODS: Body composition was measured by dual energy x-ray absorptiometry (DEXA) at hospital discharge, term, 12 weeks, and at 6 and 12 months corrected age in 125 infants (birthweight < or = 1750 g, gestational age < or = 34 weeks). RESULTS: Body weight derived by DEXA accurately predicted that determined by conventional scales. In both sexes lean mass (LM), fat mass (FM), %FM, bone area (BA), bone mineral mass (BMM), and bone mineral density (BMD) increased rapidly during the study; significant changes were detectable between discharge and term. At 12 months, LM, BA, and BMM, but not FM, %FM, or BMD were greater in boys than in girls. Corrected for age, LM was less than those of the reference term infant; FM and %FM were similar; BMM was greater. Corrected for weight, LM was similar to those of the reference infant, while the FM and %FM of study infants were slightly greater. CONCLUSIONS: DEXA accurately measures body mass. Body composition in preterm boys and girls differs. Interpretation of DEXA values may depend on whether age or body weight are regarded as the appropriate reference.
Authors: N C de Bruin; K A van Velthoven; M de Ridder; T Stijnen; R E Juttmann; H J Degenhart; H K Visser Journal: Arch Dis Child Date: 1996-05 Impact factor: 3.791
Authors: Miguel Saenz de Pipaon; Izaskun Dorronsoro; Laura Álvarez-Cuervo; Nancy F Butte; Rosario Madero; Vicente Barrios; Juan Coya; Miriam Martínez-Biarge; Gabriel Á Martos-Moreno; Mary S Fewtrell; Jesús Argente; José Quero Journal: Pediatr Res Date: 2017-07-05 Impact factor: 3.756
Authors: Kelly M Daly-Wolfe; Kristine C Jordan; Hillarie Slater; Joanna C Beachy; Laurie J Moyer-Mileur Journal: Pediatr Res Date: 2015-05-28 Impact factor: 3.756
Authors: Irfan Ahmad; Dan Nemet; Alon Eliakim; Robin Koeppel; Donna Grochow; Maria Coussens; Susan Gallitto; Julia Rich; Andria Pontello; Szu-Yun Leu; Dan M Cooper; Feizal Waffarn Journal: Am J Hum Biol Date: 2010 Jan-Feb Impact factor: 1.937
Authors: W A Huysman; M de Ridder; N C de Bruin; G van Helmond; N Terpstra; J B Van Goudoever; P J J Sauer Journal: Arch Dis Child Fetal Neonatal Ed Date: 2003-01 Impact factor: 5.747
Authors: Walter Mihatsch; Izaskun Dorronsoro Martín; Vicente Barrios-Sabador; María L Couce; Gabriel Á Martos-Moreno; Jesús Argente; José Quero; Miguel Saenz de Pipaon Journal: Nutrients Date: 2021-03-20 Impact factor: 5.717