Literature DB >> 10211806

A multiwavelength frequency-domain near-infrared cerebral oximeter.

C D Kurth1, W S Thayer.   

Abstract

This study tests a multiwavelength frequency-domain near-infrared oximeter (fdNIRS) in an in vitro model of the human brain. The model is a solid plastic structure containing a vascular network perfused with blood in which haemoglobin oxygen saturation (SO2) was measured by co-oximetry, providing a standard for comparison. Plastic shells of varying thickness (0.5-2 cm), with a vascular network of their own and encircling the brain model, were also added to simulate extracranial tissues of the infant, child and adult. The fdNIRS oximeter utilizes frequency-domain technology to monitor phaseshifts at 754 nm, 785 nm and 816 nm relative to a 780 nm reference to derive SO2 through photon transport and Beer-Lambert equations. We found a linear relationship between fdNIRS SO2 and co-oximetry SO2 with excellent correlation (r2 > or = 0.95) that fitted the line of identity in all experiments (n = 7). The bias of fdNIRS oximetry was -2% and the precision was 6%. Blood temperature and fdNIRS source-detector distance did not affect fdNIRS oximetry. Low haemoglobin concentration (6 g dl(-1)) altered the fdNIRS versus co-oximetry line slope and intercept, producing a 15% error at the extremes of SO2. The infant- and child-like shells overlying the brain model did not alter fdNIRS oximetry, whereas the adult-like shell yielded an error as high as 32%. In conclusion, fdNIRS accurately measures SO2 in an in vitro brain model, although low haemoglobin concentration and extracranial tissue of adult thickness influence accuracy.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10211806     DOI: 10.1088/0031-9155/44/3/015

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  9 in total

1.  Preoperative cerebral hemodynamics from birth to surgery in neonates with critical congenital heart disease.

Authors:  Jennifer M Lynch; Tiffany Ko; David R Busch; John J Newland; Madeline E Winters; Kobina Mensah-Brown; Timothy W Boorady; Rui Xiao; Susan C Nicolson; Lisa M Montenegro; J William Gaynor; Thomas L Spray; Arjun G Yodh; Maryam Y Naim; Daniel J Licht
Journal:  J Thorac Cardiovasc Surg       Date:  2018-05-03       Impact factor: 5.209

2.  Optical fiber probe spectroscopy for laparoscopic monitoring of tissue oxygenation during esophagectomies.

Authors:  Daniel S Gareau; Frederic Truffer; Kyle A Perry; Kyle Perry; Thai H Pham; Thai Pham; C Kristian Enestvedt; James P Dolan; James Dolan; John G Hunter; Steven L Jacques
Journal:  J Biomed Opt       Date:  2010 Nov-Dec       Impact factor: 3.170

Review 3.  Cerebral and tissue oximetry.

Authors:  Jochen Steppan; Charles W Hogue
Journal:  Best Pract Res Clin Anaesthesiol       Date:  2014-09-28

Review 4.  Brain protection in cardiac surgery.

Authors:  Kelly Grogan; Joshua Stearns; Charles W Hogue
Journal:  Anesthesiol Clin       Date:  2008-09

Review 5.  Cerebral near-infrared spectroscopy (NIRS) for perioperative monitoring of brain oxygenation in children and adults.

Authors:  Yun Yu; Kaiying Zhang; Ling Zhang; Huantao Zong; Lingzhong Meng; Ruquan Han
Journal:  Cochrane Database Syst Rev       Date:  2018-01-17

Review 6.  Frequency-Domain Techniques for Cerebral and Functional Near-Infrared Spectroscopy.

Authors:  Sergio Fantini; Angelo Sassaroli
Journal:  Front Neurosci       Date:  2020-04-07       Impact factor: 4.677

7.  PPG EduKit: An Adjustable Photoplethysmography Evaluation System for Educational Activities.

Authors:  Ángel Solé Morillo; Joan Lambert Cause; Vlad-Eusebiu Baciu; Bruno da Silva; Juan C Garcia-Naranjo; Johan Stiens
Journal:  Sensors (Basel)       Date:  2022-02-11       Impact factor: 3.576

8.  Near infrared spectroscopy (NIRS) of the thenar eminence in anesthesia and intensive care.

Authors:  Miklos Lipcsey; Nicholas Cz Woinarski; Rinaldo Bellomo
Journal:  Ann Intensive Care       Date:  2012-05-08       Impact factor: 6.925

Review 9.  Near-infrared spectroscopy for the evaluation of anesthetic depth.

Authors:  Gabriela Hernandez-Meza; Meltem Izzetoglu; Mary Osbakken; Michael Green; Kurtulus Izzetoglu
Journal:  Biomed Res Int       Date:  2015-10-01       Impact factor: 3.411

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.