Literature DB >> 10210076

Resulting tensile forces in the human bone-patellar tendon-bone graft: direct force measurement in vitro.

S Rupp1, T Hopf, T Hess, R Seil, D M Kohn.   

Abstract

The objective of this study was to measure the resultant force in the human bone-patellar tendon-bone graft after reconstruction of the anterior cruciate ligament under various conditions in vitro. Seven fresh-frozen cadaver lower extremities were used. Force measurement was made with a quartz force transducer mounted in a specially designed load cell. The effect of passive extension movement, quadriceps pull, varus torque, and valgus torque on the resultant force in the ligament were investigated. Passive extension of the joint generated a rapid increase of force in the graft between 30 degrees and 0 degrees of flexion, reaching its maximum (128+/-25 N) at full extension. When quadriceps pull was applied to extend the joint, resultant force increased at 50 degrees of flexion and reached its maximum (219+/-25 N) at full extension. Additional resistance applied to the level of the ankle joint generated an additional load of the graft. Increase of forces in the ligament resulted from both varus and valgus applied moments.

Entities:  

Mesh:

Year:  1999        PMID: 10210076     DOI: 10.1053/ar.1999.v15.0150171

Source DB:  PubMed          Journal:  Arthroscopy        ISSN: 0749-8063            Impact factor:   4.772


  9 in total

1.  ["Shrinkage of cruciate ligaments"--a biomechanical study. Shrinkage of elongated cruciate ligaments using an application of radiofrequency energy].

Authors:  A Weimann; M Jahnke; T Zantop; T Fuchs; W Drescher; W Petersen
Journal:  Unfallchirurg       Date:  2004-08       Impact factor: 1.000

2.  Bone plug length and loading angle determine the primary stability of patellar tendon-bone grafts in press-fit ACL reconstruction.

Authors:  R Schmidt-Wiethoff; J Dargel; M Gerstner; T Schneider; J Koebke
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2005-07-20       Impact factor: 4.342

3.  Failure load of patellar tendon grafts at the femoral side: 10- versus 20-mm-bone blocks.

Authors:  Duncan E Meuffels; Marnix J N Niggebrugge; Jan A N Verhaar
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2008-10-07       Impact factor: 4.342

4.  Serial dilation versus extraction drilling in anterior cruciate ligament reconstruction: a biomechanical study.

Authors:  O G Sørensen; B W Jakobsen; S Kold; T B Hansen; K Søballe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2009-09-26       Impact factor: 4.342

5.  Serial dilation reduces graft slippage compared to extraction drilling in anterior cruciate ligament reconstruction: a randomized controlled trial using radiostereometric analysis.

Authors:  O G Sørensen; K Larsen; B W Jakobsen; S Kold; T B Hansen; S Taudal; B Lund; S E Christiansen; M Lind; K Søballe
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2010-08-03       Impact factor: 4.342

6.  Biomechanical evaluation of a new cross-pin technique for the fixation of different sized bone-patellar tendon-bone grafts.

Authors:  Thore Zantop; Barbara Welbers; Andre Weimann; Markus Rümmler; Jürgen Hedderich; Volker Musahl; Wolf Petersen
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-06-19       Impact factor: 4.342

7.  Fixation strength of a novel bioabsorbable expansion bolt for patellar tendon bone graft fixation: an experimental study in calf tibial bone.

Authors:  Stefan Piltz; Patrick Strunk; Ludger Meyer; Wolfgang Plitz; Guenter Lob
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2004-03-24       Impact factor: 4.342

8.  Bioabsorbable Versus Metal Screw in the Fixation of Tibial Tubercle Transfer: A Cadaveric Biomechanical Study.

Authors:  Janne T Nurmi; Ari Itälä; Raine Sihvonen; Petri Sillanpää; Pekka Kannus; Harri Sievänen; Teppo L N Järvinen
Journal:  Orthop J Sports Med       Date:  2017-07-10

9.  Comparison of Pull-out Strength for Different Bone Block Length in a Porcine Anterior Cruciate Ligament Model.

Authors:  Matthew Posner; Brett Owens; Paul Johnson; Noreen Masciello; Kenneth Cameron; Christopher Roach; Steven Svoboda; Bruce Floersheim
Journal:  Orthop J Sports Med       Date:  2014-05-12
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.