Literature DB >> 10208215

Evaluation of electrical impedance tomography in the measurement of PEEP-induced changes in lung volume.

P W Kunst1, P M de Vries, P E Postmus, J Bakker.   

Abstract

STUDY
OBJECTIVES: A new noninvasive practical technique called electrical impedance tomography (EIT) was examined for the measurement of alveolar recruitment.
DESIGN: Prospective clinical study.
SETTING: ICU of a general hospital. PATIENTS: Acute respiratory failure (ARF) patients. MEASUREMENTS: The ventilation-induced impedance changes (VICs) of the nondependent and the dependent part of the lung were determined by EIT as a measure of tidal volume distribution. By the use of an impedance ratio (IR), defined as the VIC of the nondependent part of the lung divided by the VIC of the dependent part of the lung, the ventilation performances in both parts of the lung were compared to each other.
RESULTS: Between patients, the VIC of the nondependent part of the lung was significantly lower in the patients with a level of positive end-expiratory pressure (PEEP) of > 10 cm H2O than in patients with a PEEP of < 5 cm H2O (p < 0.05). A significantly lower IR (-/+ SD) was found in the group with PEEP of > 10 cm H2O than in the group with PEEP between 0 and 5 cm H2O (1.28+/-0.58 vs 2.99+/-1.24, respectively; p < 0.01). In individual patients, the VIC of the whole lung increased when the PEEP level was increased. The VICs of the nondependent part of the lung and of the dependent part of the lung showed significant increases at a PEEP of 10 cm H2O compared to a PEEP of 0 cm H2O (p < 0.05). Also the IR decreased in individual patients when the PEEP was increased; a significant decrease was found at 10 cm H2O compared to 0 cm H2O (1.67+/-1.24 vs 2.23+/-1.47, respectively; p < 0.05).
CONCLUSIONS: The decrease in IR indicates an increase in VIC in the dependent part of the lung above the nondependent part of the lung. The increase in VIC can be regarded as an increase in lung volume, implying alveolar recruitment in the dependent part of the lung. The same results also have been shown in earlier reports by CT scan. Since EIT is far more practical than CT scanning and also is a bedside method, EIT might help in the adjustment of ventilator settings in ARF patients.

Entities:  

Mesh:

Year:  1999        PMID: 10208215     DOI: 10.1378/chest.115.4.1102

Source DB:  PubMed          Journal:  Chest        ISSN: 0012-3692            Impact factor:   9.410


  8 in total

1.  Distribution of lung ventilation in spontaneously breathing neonates lying in different body positions.

Authors:  Inéz Frerichs; Holger Schiffmann; Robert Oehler; Taras Dudykevych; Günter Hahn; José Hinz; Gerhard Hellige
Journal:  Intensive Care Med       Date:  2003-03-29       Impact factor: 17.440

Review 2.  Electrical impedance tomography: the holy grail of ventilation and perfusion monitoring?

Authors:  Steffen Leonhardt; Burkhard Lachmann
Journal:  Intensive Care Med       Date:  2012-09-20       Impact factor: 17.440

3.  Electrical Impedance Tomography: a new study method for neonatal Respiratory Distress Syndrome?

Authors:  I Chatziioannidis; T Samaras; N Nikolaidis
Journal:  Hippokratia       Date:  2011-07       Impact factor: 0.471

4.  Estimation of regional lung volume changes by electrical impedance pressures tomography during a pressure-volume maneuver.

Authors:  Huibert R van Genderingen; Adrianus J van Vught; Jos R C Jansen
Journal:  Intensive Care Med       Date:  2002-12-14       Impact factor: 17.440

5.  Assessment of Ventilation Distribution during Laparoscopic Bariatric Surgery: An Electrical Impedance Tomography Study.

Authors:  Michal Stankiewicz-Rudnicki; Wojciech Gaszynski; Tomasz Gaszynski
Journal:  Biomed Res Int       Date:  2016-12-12       Impact factor: 3.411

6.  Electrical impedance tomography for predicting failure of spontaneous breathing trials in patients with prolonged weaning.

Authors:  Johannes Bickenbach; Michael Czaplik; Mareike Polier; Gernot Marx; Nikolaus Marx; Michael Dreher
Journal:  Crit Care       Date:  2017-07-12       Impact factor: 9.097

7.  Pulmonary pathophysiology development of COVID-19 assessed by serial Electrical Impedance Tomography in the MaastrICCht cohort.

Authors:  Serge J H Heines; Bas C T van Bussel; Melanie J Acampo-de Jong; Frank C Bennis; Rob J J van Gassel; Rald V M Groven; Nanon F L Heijnen; Ben J M Hermans; René Hounjet; Johan van Koll; Mark M G Mulder; Marcel C G van de Poll; Frank van Rosmalen; Ruud Segers; Sander Steyns; Ulrich Strauch; Jeanette Tas; Iwan C C van der Horst; Sander M J van Kuijk; Dennis C J J Bergmans
Journal:  Sci Rep       Date:  2022-08-25       Impact factor: 4.996

8.  Lung volume calculated from electrical impedance tomography in ICU patients at different PEEP levels.

Authors:  Ido G Bikker; Steffen Leonhardt; Jan Bakker; Diederik Gommers
Journal:  Intensive Care Med       Date:  2009-06-10       Impact factor: 17.440

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.