Literature DB >> 10207649

Stereolithography versus milled three-dimensional models: comparison of production method, indication, and accuracy.

G Santler1, H Kärcher, A Gaggl, R Kern.   

Abstract

Computed tomography (CT) based three-dimensional (3-D) lifelike models have proved to be of great value, especially in craniomaxillofacial surgery. They improve and facilitate diagnosis, therapeutic planning, model operations, and definitive treatment in tumor surgery, traumatology, dysgnathia, alveolar atrophy, and congenital and asymmetrical malformations. From 1988 to 1998, 760 stereolithography (STL) and milled 3-D models were employed in our department. These two production methods have become the msot commonly used approaches, and the question as to which is preferable is the subject of controversy in the literature. Using two test models the STL and the milling method were compared with regard to production method and accuracy, and the resulting differences in indications for their use are discussed. The limiting factor for increased accuracy is the distance between each pair of CT scans. Milled models show a higher precision compared to STL models within the CT-scan plane, but the more the measurements deviate from this plane (becoming oblique) the more inaccurate the data becomes. STL exhibits greater deviations, but the inaccuracy is randomly distributed. The mean variation from the original was 0.81 mm for STL and 0.54 mm for milled models. Although 90% of the milled and 80% of the STL values are within a deviation of +/- 1 mm, it should be noted that maximum deviations of 3.15 mm in milled models and 2 mm in STL have been shown. Both methods are sufficiently accurate for clinical use. In standard cases involving the upper and lower jaw, malar bone, orbita, and calvaria the shorter production time and lower costs make milled models preferable. In special cases, in which hollows and fine structures play a major role (e.g., those involving the skull base, paranasal sinuses, inner ear, and mandibular canal), STL is indicated.

Entities:  

Mesh:

Year:  1998        PMID: 10207649     DOI: 10.1002/(SICI)1097-0150(1998)3:5<248::AID-IGS4>3.0.CO;2-A

Source DB:  PubMed          Journal:  Comput Aided Surg        ISSN: 1092-9088


  11 in total

1.  A three-dimensional finite element analysis of the relationship between masticatory performance and skeletal malocclusion.

Authors:  Jung-Chul Park; Hyun-Seung Shin; Jung-Yul Cha; Jong-Tae Park
Journal:  J Periodontal Implant Sci       Date:  2015-02-25       Impact factor: 2.614

2.  New Methods to Evaluate Craniofacial Deformity and to Plan Surgical Correction.

Authors:  Jaime Gateno; James J Xia; John F Teichgraeber
Journal:  Semin Orthod       Date:  2011-09-01       Impact factor: 0.970

3.  Calcaneal osteotomy preoperative planning system with 3D full-sized computer-assisted technology.

Authors:  Yi-Jiun Chou; Shuh-Ping Sun; Hsin-Hua Liu
Journal:  J Med Syst       Date:  2010-03-30       Impact factor: 4.460

4.  Accuracy of a computer-aided surgical simulation protocol for orthognathic surgery: a prospective multicenter study.

Authors:  Sam Sheng-Pin Hsu; Jaime Gateno; R Bryan Bell; David L Hirsch; Michael R Markiewicz; John F Teichgraeber; Xiaobo Zhou; James J Xia
Journal:  J Oral Maxillofac Surg       Date:  2012-06-12       Impact factor: 1.895

5.  An experimental method for stereolithic mandible fabrication and image preparation.

Authors:  Shawn Russett; Paul Major; Jason Carey; Roger Toogood; Pierre Boulanger
Journal:  Open Biomed Eng J       Date:  2007-07-17

6.  New clinical protocol to evaluate craniomaxillofacial deformity and plan surgical correction.

Authors:  James J Xia; Jaime Gateno; John F Teichgraeber
Journal:  J Oral Maxillofac Surg       Date:  2009-10       Impact factor: 1.895

7.  Accuracy and reliability of craniometric measurements on lateral cephalometry and 3D measurements on CBCT scans.

Authors:  Bruno Frazäo Gribel; Marcos Nadler Gribel; Diogo Campos Frazäo; James A McNamara; Flavio Ricardo Manzi
Journal:  Angle Orthod       Date:  2011-01       Impact factor: 2.079

8.  Prototyping of cerebral vasculature physical models.

Authors:  Imad S Khan; Patrick D Kelly; Robert J Singer
Journal:  Surg Neurol Int       Date:  2014-01-27

9.  Evaluation of 3-dimensional superimposition techniques on various skeletal structures of the head using surface models.

Authors:  Nikolaos Gkantidis; Michael Schauseil; Pawel Pazera; Berna Zorkun; Christos Katsaros; Björn Ludwig
Journal:  PLoS One       Date:  2015-02-23       Impact factor: 3.240

10.  Homo floresiensis contextualized: a geometric morphometric comparative analysis of fossil and pathological human samples.

Authors:  Karen L Baab; Kieran P McNulty; Katerina Harvati
Journal:  PLoS One       Date:  2013-07-10       Impact factor: 3.240

View more