Literature DB >> 10207552

Evaluation of HIV serial and parallel serologic testing algorithms in Abidjan, Côte d'Ivoire.

J N Nkengasong1, C Maurice, S Koblavi, M Kalou, D Yavo, M Maran, C Bile, K N'guessan, J Kouadio, S Bony, S Z Wiktor, A E Greenberg.   

Abstract

OBJECTIVE: To evaluate HIV serologic testing algorithms based on a combination of three enzyme linked immunosorbent assays (ELISA) for the confirmation of HIV infection in Abidjan, Côte d'Ivoire, where HIV-2 and HIV-1 non-B subtypes are prevalent.
METHODS: A total of 1069 human sera with known serologic status, in addition to a seroconversion and low titer antibody panel were initially tested by six ELISA to determine the sensitivity, specificity and delta values of the assays. On the basis of the performance of the assays, three ELISA (Enzygnost, ICE 1.0.2, and Vironostika) were selected for use in a parallel and serial testing algorithm in analyzing 8283 consecutively collected sera. In the parallel testing algorithm, sera concordantly reactive or non-reactive by Enzygnost and ICE 1.0.2 were considered as true positive or true negative, respectively. In the serial algorithm, sera reactive by Enzygnost were retested by ICE 1.0.2. Sera with discordant results were tested by Vironostika, and the results was considered definitive. All reactive sera, plus a random sample of negative sera were tested for confirmation by Peptilav. In addition, a random sample of reactive sera was tested by Western blot.
RESULTS: All ELISA had 100% sensitivity; specificities ranged from 96.8 to 100%. Positive and negative delta values of the ELISA were high (range, 6.89 to 46.07 and -2.05 to -5.75, respectively). Of the 8283 sera, 2054 were considered true positives and were correctly classified by the parallel testing algorithm (sensitivity, 100%). Of the 6229 true negative sera, 6226 were negative by the parallel testing algorithm (specificity, 99.95%). The sensitivity of the serial algorithm was 99.96%, and specificity was 99.95%. None of the 250 concordant ELISA-negative sera in the algorithm that were randomly tested in Peptilav was positive; similarly, all of the 103 concordant ELISA-positive sera were confirmed by Western blot. The three-ELISA algorithm resulted in reagent cost-savings of at least 50% compared with the Peptilav-based algorithm.
CONCLUSION: These results suggest that a combination of ELISA using different principles or antigens in a serial or parallel algorithm is an efficient and cost-effective alternative to the standard algorithm in areas where HIV-1 and HIV-2 are prevalent.

Entities:  

Mesh:

Year:  1999        PMID: 10207552     DOI: 10.1097/00002030-199901140-00015

Source DB:  PubMed          Journal:  AIDS        ISSN: 0269-9370            Impact factor:   4.177


  8 in total

1.  A serial risk score approach to disease classification that accounts for accuracy and cost.

Authors:  Dat Huynh; Oliver Laeyendecker; Ron Brookmeyer
Journal:  Biometrics       Date:  2014-08-25       Impact factor: 2.571

2.  Sensitivity and specificity of human immunodeficiency virus rapid serologic assays and testing algorithms in an antenatal clinic in Abidjan, Ivory Coast.

Authors:  S Koblavi-Dème; C Maurice; D Yavo; T S Sibailly; K N'guessan; Y Kamelan-Tano; S Z Wiktor; T H Roels; T Chorba; J N Nkengasong
Journal:  J Clin Microbiol       Date:  2001-05       Impact factor: 5.948

3.  Technological challenges in diagnosis and management of HIV infection in resource limited settings.

Authors:  Purnima Madhivanan; Karl Krupp
Journal:  BMJ       Date:  2007-07-28

4.  Assessment of CD8 T cell immune activation markers to monitor response to antiretroviral therapy among HIV-1 infected patients in Côte d'Ivoire.

Authors:  P Ondoa; S Koblavi-Dème; M-Y Borget; M L Nolan; J N Nkengasong; L Kestens
Journal:  Clin Exp Immunol       Date:  2005-04       Impact factor: 4.330

5.  Evaluation and diagnostic usefulness of domestic and imported enzyme-linked immunosorbent assays for detection of human immunodeficiency virus type 1 antibody in India.

Authors:  H Syed Iqbal; Suniti Solomon; K G Murugavel; Sunil Suhas Solomon; P Balakrishnan
Journal:  Clin Diagn Lab Immunol       Date:  2005-12

6.  Field evaluation of the gag-based heteroduplex mobility assay for genetic subtyping of circulating recombinant forms of human immunodeficiency virus type 1 in Abidjan, Côte d'Ivoire.

Authors:  Souleymane Sawadogo; Christiane Adjé-Touré; Celestin E Bilé; Rene E A Ekpini; Terence Chorba; John N Nkengasong
Journal:  J Clin Microbiol       Date:  2003-07       Impact factor: 5.948

7.  Assessing the relationship between HIV infection and cervical cancer in Côte d'Ivoire: a case-control study.

Authors:  Georgette Adjorlolo-Johnson; Elizabeth R Unger; Edith Boni-Ouattara; Kadidiata Touré-Coulibaly; Chantal Maurice; Suzanne D Vernon; Marcel Sissoko; Alan E Greenberg; Stefan Z Wiktor; Terence L Chorba
Journal:  BMC Infect Dis       Date:  2010-08-17       Impact factor: 3.090

8.  HIV serologically indeterminate individuals: Future HIV status and risk factors.

Authors:  George Mwinnyaa; Mary K Grabowski; Ronald H Gray; Maria Wawer; Larry W Chang; Joseph Ssekasanvu; Joseph Kagaayi; Godfrey Kigozi; Sarah Kalibbala; Ronald M Galiwango; Anthony Ndyanabo; David Serwadda; Thomas C Quinn; Steven J Reynolds; Oliver Laeyendecker
Journal:  PLoS One       Date:  2020-08-26       Impact factor: 3.240

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.