Literature DB >> 10207484

Stereotactic, automated, large-core needle biopsy of nonpalpable breast lesions: false-negative and histologic underestimation rates after long-term follow-up.

R J Jackman1, K W Nowels, J Rodriguez-Soto, F A Marzoni, S I Finkelstein, M J Shepard.   

Abstract

PURPOSE: To determine the rate and causes of false-negative findings and histologic underestimates at stereotactic biopsy of nonpalpable breast lesions.
MATERIALS AND METHODS: Stereotactic, 14-gauge, automated, large-core needle biopsy (LCNB) was performed in 483 consecutive nonpalpable breast lesions. Excision was advised for the 143 carcinomas, 25 atypical ductal hyperplasia (ADH) lesions, and five radial scars. Mammographic follow-up was advised for the benign lesions without a repeat biopsy.
RESULTS: Of the 310 benign lesions, 259 underwent mammographic follow-up at 6-85 months (median, 55 months) without repeat biopsy, 48 underwent repeat biopsy and three were lost to follow-up. On the basis of the histologic diagnosis of carcinoma at surgical biopsy, diagnosis with LCNB was not correct (i.e., disease was underestimated at histologic examination) in 14 (58%) of 24 ADH lesions and two (40%) of five radial scars. Two (1.2%) of 161 lesions with a final diagnosis of carcinoma were benign at LCNB but malignant at repeat biopsy (i.e., false-negative findings at LCNB). Repeat biopsy was prompted by mammographic progression at 6 and 18 months after LCNB.
CONCLUSION: The false-negative rate with LCNB was 1.2% in this study and 4.0% in the literature. The presence of carcinoma in ADH and radial scar lesions was often underestimated.

Entities:  

Mesh:

Year:  1999        PMID: 10207484     DOI: 10.1148/radiology.210.3.r99mr19799

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  45 in total

Review 1.  Pathology and clinical relevance of radial scars: a review.

Authors:  M Kennedy; A V Masterson; M Kerin; F Flanagan
Journal:  J Clin Pathol       Date:  2003-10       Impact factor: 3.411

Review 2.  Stereotactic and ultrasound-guided breast biopsy.

Authors:  T H Helbich; W Matzek; M H Fuchsjäger
Journal:  Eur Radiol       Date:  2003-11-13       Impact factor: 5.315

3.  The radial scar of the breast diagnosed at core needle biopsy.

Authors:  Cory Morgan; Zeeshan A Shah; Raynal Hamilton; Jean Wang; Joseph Spigel; William Deleon; Patricia Deleon; Tyler Leete; J Mark Fulmer
Journal:  Proc (Bayl Univ Med Cent)       Date:  2012-01

4.  Clinical Images: Radial Scar of the Breast.

Authors:  Dana H Smetherman; Lena Fathi Gowharji
Journal:  Ochsner J       Date:  2015

5.  Can galactography-guided stereotactic, 11-gauge, vacuum-assisted breast biopsy of intraductal lesions serve as an alternative to surgical biopsy?

Authors:  Caecilia S Reiner; Thomas H Helbich; Margaretha Rudas; Lothar Ponhold; Christopher C Riedl; Nina Kropf; Michael H Fuchsjäger
Journal:  Eur Radiol       Date:  2009-12       Impact factor: 5.315

6.  Stereotactic core-needle breast biopsy by surgeons: minimum 2-year follow-up of benign lesions.

Authors:  R P Burns; J P Brown; S M Roe; L R Sprouse; A E Yancey; L E Witherspoon
Journal:  Ann Surg       Date:  2000-10       Impact factor: 12.969

7.  Factors associated with upstaging of ductal carcinoma in situ diagnosed by core needle biopsy using imaging guidance.

Authors:  Cholatip Wiratkapun; Pachara Patanajareet; Bussanee Wibulpholprasert; Panuwat Lertsithichai
Journal:  Jpn J Radiol       Date:  2011-09-17       Impact factor: 2.374

8.  Additional diagnostic value of MRI in patients with suspicious breast lesions based on ultrasound.

Authors:  O Sarica; F Uluc
Journal:  Br J Radiol       Date:  2014-07-01       Impact factor: 3.039

9.  [Sonographically guided, minimally invasive biopsy of uncertain mammary lesions. Clinical experience with a new biopsy system].

Authors:  H Sittek; A Wieser; M Kessler; S Britsch; C Vick; M Untch; M Reiser
Journal:  Radiologe       Date:  2005-03       Impact factor: 0.635

10.  Surgical outcomes of borderline breast lesions detected by needle biopsy in a breast screening program.

Authors:  Karen M Flegg; Jeffrey J Flaherty; Anne M Bicknell; Sanjiv Jain
Journal:  World J Surg Oncol       Date:  2010-09-08       Impact factor: 2.754