Influence of the modification of P/L ratio on a new formulation of acrylic bone cement.

B Pascual1, M Gurruchaga, M P Ginebra, F J Gil, J A Planell, I Goñi.   

Abstract

The use of smaller powder/liquid (P/L) ratio favours the handling and wetting of poly(methyl methacrylate) (PMMA) beads in bone cement formulations. In this paper a P/L ratio of 1.86 is tested to overcome adhesion problems found in hydroxypropyl methacrylate (HPMA) modified bone cements and the influence on bone cement characteristics was analysed. The reduction of the P/L ratio leads to higher temperature peaks and shorter setting times, whereas the residual monomer content increases slightly. Water uptake obeys the diffusion laws, and the introduction of a more hydrophilic monomer gives rise to an increase of this parameter, which does not present significant changes with modification of the P/L ratio. Polymerization shrinkage is slightly greater because of the introduction of higher proportions of monomer in the formulation. Mechanical properties are similar to those obtained with conventional P/L ratios. The analysis of scanning electron microscopy (SEM) reveals an improvement of the adhesion between phases with respect to P/L = 2 formulations.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10204989     DOI: 10.1016/s0142-9612(98)00192-6

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  4 in total

1.  New radiopaque acrylic bone cement. II. Acrylic bone cement with bromine-containing monomer.

Authors:  M C Rusu; I C Ichim; M Popa; M Rusu
Journal:  J Mater Sci Mater Med       Date:  2008-01-16       Impact factor: 3.896

2.  Mechanical Characterization of Dental Prostheses Manufactured with PMMA-Graphene Composites.

Authors:  Miquel Punset; Aritza Brizuela; Esteban Pérez-Pevida; Mariano Herrero-Climent; José Maria Manero; Javier Gil
Journal:  Materials (Basel)       Date:  2022-08-05       Impact factor: 3.748

3.  Concepts for increasing gentamicin release from handmade bone cement beads.

Authors:  Hermawan N Rasyid; Henny C van der Mei; Henderik W Frijlink; Soegijardjo Soegijoko; Jim R van Horn; Henk J Busscher; Daniëlle Neut
Journal:  Acta Orthop       Date:  2009-10       Impact factor: 3.717

4.  Comparative evaluation of color stability of three commercially available provisional restorative materials: An in vitro study.

Authors:  Cora Abigail Coutinho; Divya Hegde; Vinita Sanjeevan; Ivy Fernandes Coutinho; Akansha Priya
Journal:  J Indian Prosthodont Soc       Date:  2021 Apr-Jun
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.