Literature DB >> 10204880

3D coronary artery imaging with phase reordering for improved scan efficiency.

P Jhooti1, J Keegan, P D Gatehouse, S Collins, A Rowe, A M Taylor, D N Firmin.   

Abstract

Three-dimensional (3D) coronary imaging has the potential to overcome problems resulting from vessel tortuosity and to reduce partial volume effects. With these techniques, however, acquisition times are long and respiratory motion artifacts problematical. This work describes the development of a method that applies phase encode reordering to 3D acquisitions, allowing larger navigator acceptance windows to be used, with a consequent reduction in acquisition time. This method is compared with navigator acceptance window methods (the acceptance-rejection algorithm and the diminishing variance algorithm) and the retrospective respiratory gating technique, both in vitro and in vivo. The use of phase reordering with a 10 mm acceptance window provided a significant increase in scan efficiency over a non-reordered 5 mm method (P<0.001) with no significant change in image quality, and a significant increase in image quality compared with a non-reordered image acquired in the same time (P<0.05). A significant improvement in both image quality and scan efficiency was demonstrated over the retrospective respiratory gating method (P<0.05).

Mesh:

Year:  1999        PMID: 10204880     DOI: 10.1002/(sici)1522-2594(199903)41:3<555::aid-mrm19>3.0.co;2-i

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  5 in total

1.  Prospective navigator gating with a dual acceptance window technique to reduce respiratory motion artifacts in 3D MR coronary angiography.

Authors:  Yiping P Du
Journal:  Int J Cardiovasc Imaging       Date:  2003-04       Impact factor: 2.357

2.  A Platform Integrating Acquisition, Reconstruction, Visualization, and Manipulator Control Modules for MRI-Guided Interventions.

Authors:  Jose D Velazco Garcia; Nikhil V Navkar; Dawei Gui; Cristina M Morales; Eftychios G Christoforou; Alpay Ozcan; Julien Abinahed; Abdulla Al-Ansari; Andrew Webb; Ioannis Seimenis; Nikolaos V Tsekos
Journal:  J Digit Imaging       Date:  2019-06       Impact factor: 4.056

3.  Free-breathing cardiac MR with a fixed navigator efficiency using adaptive gating window size.

Authors:  Mehdi H Moghari; Raymond H Chan; Susie N Hong; Jaime L Shaw; Lois A Goepfert; Kraig V Kissinger; Beth Goddu; Mark E Josephson; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-02-24       Impact factor: 4.668

4.  Free-breathing 3D cardiac MRI using iterative image-based respiratory motion correction.

Authors:  Mehdi H Moghari; Sébastien Roujol; Raymond H Chan; Susie N Hong; Natalie Bello; Markus Henningsson; Long H Ngo; Beth Goddu; Lois Goepfert; Kraig V Kissinger; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2012-11-06       Impact factor: 4.668

Review 5.  Advanced respiratory motion compensation for coronary MR angiography.

Authors:  Markus Henningsson; Rene M Botnar
Journal:  Sensors (Basel)       Date:  2013-05-24       Impact factor: 3.576

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.