Literature DB >> 10204441

Laser and curing light induced in vitro pulpal temperature changes.

G L Powell1, J R Anderson, R J Blankenau.   

Abstract

OBJECTIVE: This study was conducted to compare in vitro pulp chamber temperature changes induced by conventional curing light and argon laser under common conditions. SUMMARY BACKGROUND DATA: Previous in vitro studies have shown that impacting the surface of teeth with either an argon laser or conventional curing light causes pulp temperature increases of various degrees.
METHODS: The sample tooth had a class V composite restoration placed with 2.48-mm distance from the surface of the composite to a Thermister Thermometer. The thermometer was inserted into the cutaway pulp chamber to measure the temperature increase from stabilized room temperature, which was caused by exposure to argon laser or conventional curing light.
RESULTS: Temperature increases for the argon laser for the recommended curing time were 3 degrees F or less. The longer the exposure times for either method of curing, the higher the temperature increased.
CONCLUSION: At recommended curing times, in vitro pulp chamber temperature increases from laser units were significantly lower than those of the conventional curing lights.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10204441     DOI: 10.1089/clm.1999.17.3

Source DB:  PubMed          Journal:  J Clin Laser Med Surg        ISSN: 1044-5471


  4 in total

1.  In vitro analysis of human tooth pulp chamber temperature after low-intensity laser therapy at different power outputs.

Authors:  Márcio de Alencar Mollo; Lucio Frigo; Giovani Marino Favero; Rodrigo Alvaro Brandão Lopes-Martins; Aldo Brugnera Junior
Journal:  Lasers Med Sci       Date:  2010-02-11       Impact factor: 3.161

2.  Comparison of temperature increase in in vitro human tooth pulp by different light sources in the dental whitening process.

Authors:  Daniela Soares Coutinho; Landulfo Silveira; Renata Amadei Nicolau; Fátima Zanin; Aldo Brugnera
Journal:  Lasers Med Sci       Date:  2008-02-15       Impact factor: 3.161

3.  Micro-hardness evaluation of a micro-hybrid composite resin light cured with halogen light, light-emitting diode and argon ion laser.

Authors:  Katia M Rode; Patricia M de Freitas; Patricia R Lloret; Lynn G Powell; Miriam L Turbino
Journal:  Lasers Med Sci       Date:  2007-12-05       Impact factor: 3.161

4.  Use of FT-Raman Spectroscopy to Determine the Degree of Polymerization of Dental Composite Resin Cured with a New Light Source.

Authors:  Safaa K H Khalil; Mousa A Allam; Wael A Tawfik
Journal:  Eur J Dent       Date:  2007-04
  4 in total