Literature DB >> 10202950

A trial for the quantification of regional myocardial blood flow with continuous infusion of Tc-99m MIBI and dynamic SPECT.

T Tsuchida1, Y Yonekura, N Takahashi, A Nakano, J D Lee, N Sadato, K Yamamoto, A Waki, K Sugimoto, N Hayashi, Y Ishii.   

Abstract

UNLABELLED: We propose a new method to quantify regional myocardial blood flow (rMBF) by continuous infusion of Tc-99m MIBI and dynamic SPECT.
METHODS: Five patients with old myocardial infarction were studied. During continuous infusion of MIBI (approximately 740 MBq) with a syringe pump in 10 min, dynamic SPECT scan was performed every minute and lasted 20 min after the start of infusion to identify myocardial uptake of MIBI. Input function was obtained from the radioactivity in the left ventricle (LV) in dynamic SPECT images. Spillover fraction between LV and myocardium (M) was corrected with phantom data. The influx constant (Ku) was calculated by Patlak plot graphical analysis, and compared with rMBF measured by PET (F) with N-13 ammonia based on Patlak plot analysis with correction for the extraction fraction. To correct the limited first-pass extraction of MIBI, linearization correction by means of the permeability-surface area (PS) product value was also applied.
RESULTS: Spillover fractions of MIBI were 0.169+/-0.056 from LV to M, and 0.042+/-0.021 from M to LV. Ku was well correlated with F (Ku = 0.057 + 0.220F, r = 0.83, p < 0.01) and the slope and correlation were improved after linearizaiton (F(MIBI) = -0.131+0.858F, r = 0.94, p < 0.01).
CONCLUSION: The proposed method has the potential to be a clinically feasible tool for quantitative measurement of rMBF.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10202950     DOI: 10.1007/bf03165431

Source DB:  PubMed          Journal:  Ann Nucl Med        ISSN: 0914-7187            Impact factor:   2.668


  3 in total

1.  Myocardial blood flow measurement with a conventional dual-head SPECT/CT with spatiotemporal iterative reconstructions - a clinical feasibility study.

Authors:  Fares Alhassen; Nhan Nguyen; Sukhkarn Bains; Robert G Gould; Youngho Seo; Stephen L Bacharach; Xiyun Song; Lingxiong Shao; Grant T Gullberg; Carina Mari Aparici
Journal:  Am J Nucl Med Mol Imaging       Date:  2013-12-15

2.  Development of a dynamic myocardial perfusion phantom model for tracer kinetic measurements.

Authors:  Marije E Kamphuis; Henny Kuipers; Jacqueline Verschoor; Johannes C G van Hespen; Marcel J W Greuter; Riemer H J A Slart; Cornelis H Slump
Journal:  EJNMMI Phys       Date:  2022-04-25

3.  Absolute myocardial blood flows derived by dynamic CZT scan vs invasive fractional flow reserve: Correlation and accuracy.

Authors:  Konstantin V Zavadovsky; Andrew V Mochula; Alla A Boshchenko; Alexander V Vrublevsky; Andrew E Baev; Alexander L Krylov; Marina O Gulya; Evgeny A Nesterov; Riccardo Liga; Alessia Gimelli
Journal:  J Nucl Cardiol       Date:  2019-03-07       Impact factor: 5.952

  3 in total