Literature DB >> 10196837

Corrosion in stainless-steel and nickel-titanium files.

O W Stokes1, P M Fiore, J T Barss, A Koerber, J L Gilbert, E P Lautenschlager.   

Abstract

This study evaluated and compared the corrosion susceptibility of stainless-steel and nickel-titanium (NiTi) endodontic files immersed in sodium hypochlorite. For each of the stainless-steel files (Kerr K-Flex, Caulk Flex-O, and Union Broach Flex-R) plus the NiTi files (Union Broach NiTi and Tulsa NiTi), the cutting flutes of 24 ISO size 20 files were immersed into 5.25% sodium hypochlorite. Their open circuit potential (OCP) was recorded for 1 h on a strip chart with high impedance. The strip chart recording for each file was classified into a stability score: (i) stable, (ii) unstable, or (iii) erratic. The OCP was measured by a potentiostat and a standard calomel electrode reference. The OCP classification of unstable and erratic for the files evaluated were as follows: K-Flex (16%), Flex-R (12%), Flex-O (75%), Union Broach NiTi (62%), and Tulsa NiTi (0%). After OCP testing, each of the 120 files was inspected by light microscopy at x 25. The frequencies of visually observed corrosion were detected as follows: K-Flex (2/24), Flex-R (1/24), Flex-O (6/24), Union Broach NiTi (2/24), and Tulsa NiTi (0/24). There was a significant difference in corrosion frequency between brands when evaluated by OCP and light microscopy; however, there was no significant difference between stainless steel and NiTi.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10196837     DOI: 10.1016/s0099-2399(99)80392-6

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  7 in total

1.  Wear resistance of nickel-titanium endodontic files after surface treatment.

Authors:  A P R Alves-Claro; F A E Claro; E T Uzumaki
Journal:  J Mater Sci Mater Med       Date:  2008-05-13       Impact factor: 3.896

2.  Electrochemical corrosion assessment of RaCe and Mtwo rotary nickle-titanium instruments after clinical use and sterilization.

Authors:  S Shahi; H Mokhtari; S Rahimi; V Shiezadeh; H Ashasi; M Abdolrahimi; M Foroughreyhani
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2012-03-01

3.  Susceptibility of Escherichia coli O157:H7 grown at low temperatures to the krypton-chlorine excilamp.

Authors:  Jae-Ik Lee; Sang-Soon Kim; Dong-Hyun Kang
Journal:  Sci Rep       Date:  2019-01-24       Impact factor: 4.379

4.  Corrosion resistance assessment of nickel-titanium endodontic files with and without heat treatment.

Authors:  Tatiana Dias Costa; Elison da Fonseca E Silva; Paula Liparini Caetano; Marcio José da Silva Campos; Leandro Marques Resende; André Guimarães Machado; Antônio Márcio Resende do Carmo
Journal:  Restor Dent Endod       Date:  2020-12-28

5.  Effect of sodium hypochlorite on conventional and heat-treated nickel-titanium endodontic rotary instruments - An in vitro study.

Authors:  Jack Han-Hsing Lin; Bekir Karabucak; Su-Min Lee
Journal:  J Dent Sci       Date:  2020-09-14       Impact factor: 2.080

6.  Qualitative Assessment of the Surface Topographic Changes of XP-endo Shaper and TruNatomy files after exposure to Sodium Hypochlorite and Ethylenediaminetetraacetic Acid.

Authors:  Jerry Jose; Akshay Khandelwal; Riluwan Siddique
Journal:  Eur Endod J       Date:  2021-08

7.  Physical Properties of Five Brands of K-Files.

Authors:  Arash Izadi; Arash Shahravan; Hoda Shabani Nejad
Journal:  Iran Endod J       Date:  2016-03-20
  7 in total