Dose-area product readings for fluoroscopic and plain film examinations, including an analysis of the source of variation for barium enema examinations.

H M Warren-Forward1, M J Haddaway, D H Temperton, I W McCall.   

Abstract

This paper contains the results of an investigation undertaken between 1994 and 1996 using dose-area product (DAP) meters for monitoring radiation doses from six types of simple examinations and seven types of complex examinations. Mean hospital DAP levels have been compared with National Reference Levels (NRL), with most departments producing levels lower than NRLs. DAP readings have allowed the proposal of provisional Reference Levels (RL) to be set for simple and complex examinations. The results were also compared with recently published data from the National Radiological Protection Board (NRPB), highlighting those hospitals which need to make changes in radiographic technique. The study of DAP reference doses also confirms that dose levels for complex investigations are clearly related to technique, in terms of screening time and number of films. Although the use of increased screening tube kilovoltage may be relevant, the overall effect is small. The results suggest that there is still a need to optimize the protocols for these examinations. The use of digital equipment has been shown to have a complex effect on dose, particularly in the case of investigations involving both films and fluoroscopy.

Entities:  

Mesh:

Substances:

Year:  1998        PMID: 10195012     DOI: 10.1259/bjr.71.849.10195012

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  4 in total

1.  Investigation into patient doses for intravenous urography and proposed Irish diagnostic reference levels.

Authors:  E M Carroll; P C Brennan
Journal:  Eur Radiol       Date:  2003-01-22       Impact factor: 5.315

2.  The impact of endoscopic retrograde cholangiopancreatography education on radiation exposure to experienced endoscopist: 'trainee effect'.

Authors:  Erkin Oztas; Erkan Parlak; Fahrettin Kucukay; Mehmet Arhan; Ulku Daglı; Digdem Ozer Etik; Fatih Oguz Onder; Tulay Olcer; Nurgul Sasmaz
Journal:  Dig Dis Sci       Date:  2012-05       Impact factor: 3.199

3.  Effect of physician training on fluoroscopy time during ERCP.

Authors:  Lance T Uradomo; Mark E Lustberg; Peter E Darwin
Journal:  Dig Dis Sci       Date:  2006-05-23       Impact factor: 3.199

4.  Investigation of reference levels and radiation dose associated with abdominal EVAR (endovascular aneurysm repair) procedures across several European Centres.

Authors:  E Tuthill; L O'Hora; M O'Donohoe; S Panci; P Gilligan; D Campion; R Trenti; E Fox; D Catania; L Rainford
Journal:  Eur Radiol       Date:  2017-05-18       Impact factor: 5.315

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.