Literature DB >> 10193103

The effect of dentine location and tubule orientation on the bond strengths between resin and dentine.

S Phrukkanon1, M F Burrow, M J Tyas.   

Abstract

This study determined the influence of dentine structure on the micro-tensile bond strengths between resin and dentine of two different dentine adhesive systems (Single Bond, 3M Dental Products, St Paul, MN; MF-102 (experimental self-etching primer), GC Corporation, Tokyo, Japan). The study was separated into two main parts: bond strength measurement and investigation of the bonding interface. Twenty-two human premolars were used for the bond strength measurement. Each tooth was cut vertically, separating the tooth into mesio-distal halves. One half of the tooth was used to bond to a surface perpendicular to the dentinal tubules and other half to bond to a surface parallel to the tubules. For each half, six locations of dentine were bonded. Each material was used in accordance to the manufacturer's directions. Cylindrical hourglass-shaped specimens of 1.2 mm diameter at the bonded interface were manufactured. The bonds were stressed in tension at a crosshead speed of 1 mm/min. Mean bond strengths were compared using LSD, one-way ANOVA, and Student's t-test. The fractured surfaces were examined under a scanning electron microscope, and the frequency of fracture modes was compared using the Kruskal-Wallis and Mann-Whitney U tests. For the investigation of the bonded interface, four teeth were prepared by the same procedure used for the bond test specimens. The bonded interfaces were observed after an acid-base treatment or fracturing across the bonded interface, prior to investigation with a field-emission scanning electron microscope. For Single Bond, the bond strengths for mid-root dentine were significantly lower than for other locations (p < 0.05). For MF-102, there was no significant difference for all locations (p > 0.05). MF-102 bonded well to all locations of dentine while Single Bond showed a porous zone at the base of the hybrid layer. The bonds were not influenced by tubule orientation. The results indicate that the bond for Single Bond may be affected by its ability to penetrate demineralised dentine in different locations of a tooth. The self-etching primer of MF-102 produces a good bond and is independent of the position on the tooth.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10193103     DOI: 10.1016/s0300-5712(98)00060-8

Source DB:  PubMed          Journal:  J Dent        ISSN: 0300-5712            Impact factor:   4.379


  10 in total

1.  Micromechanical analysis of dentin/adhesive interface by the finite element method.

Authors:  Anil Misra; Paulette Spencer; Orestes Marangos; Yong Wang; J Lawrence Katz
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2004-07-15       Impact factor: 3.368

2.  Parametric study of the effect of phase anisotropy on the micromechanical behaviour of dentin-adhesive interfaces.

Authors:  Anil Misra; Paulette Spencer; Orestes Marangos; Yong Wang; J Lawrence Katz
Journal:  J R Soc Interface       Date:  2005-06-22       Impact factor: 4.118

3.  Adhesion after erbium, chromium:yttrium-scandium-gallium-garnet laser application at three different irradiation conditions.

Authors:  Sérgio Brossi Botta; Patricia Aparecida da Ana; Denise Maria Zezell; John M Powers; Adriana Bona Matos
Journal:  Lasers Med Sci       Date:  2007-11-20       Impact factor: 3.161

4.  SEM evaluation of resin-carious dentin interfaces formed by two dentin adhesive systems.

Authors:  Kuang-Wei Hsu; Sally J Marshall; Lilliam M Pinzon; Larry Watanabe; Eduardo Saiz; Grayson W Marshall
Journal:  Dent Mater       Date:  2007-12-21       Impact factor: 5.304

5.  Impact of Dentinal Tubule Orientation on Dentin Bond Strength.

Authors:  Jing Guo; Li-Ping Wang; Jia Zhu; Jian Yang; Hong-Shui Zhu
Journal:  Curr Med Sci       Date:  2018-08-20

6.  On the durability of resin-dentin bonds: Identifying the weakest links.

Authors:  Zihou Zhang; Dylan Beitzel; Mustafa Mutluay; Franklin R Tay; David H Pashley; Dwayne Arola
Journal:  Dent Mater       Date:  2015-07-10       Impact factor: 5.304

7.  Effect of artificial saliva contamination on bond strength to pulp chamber dentin.

Authors:  Hale Arı; Nazmiye Dönmez; Sema Belli
Journal:  Eur J Dent       Date:  2008-04

Review 8.  Validity of bond strength tests: A critical review-Part II.

Authors:  Kantheti Sirisha; Tankonda Rambabu; Yalavarthi Ravishankar; Pabbati Ravikumar
Journal:  J Conserv Dent       Date:  2014-09

9.  Nanoleakage of Class V Resin Restorations Using Two Nanofilled Adhesive Systems.

Authors:  Ebaa I Al-Agha; Mustafa I Alagha
Journal:  J Int Oral Health       Date:  2015-07

Review 10.  Assessment of Bonding Effectiveness of Adhesive Materials to Tooth Structure using Bond Strength Test Methods: A Review of Literature.

Authors:  Aminah M El Mourad
Journal:  Open Dent J       Date:  2018-09-28
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.