Literature DB >> 10189455

Single-dose breath-hold gadolinium-enhanced three-dimensional MR angiography of the renal arteries.

V S Lee1, N M Rofsky, G A Krinsky, D H Stemerman, J C Weinreb.   

Abstract

PURPOSE: To evaluate the quality of single-dose breath-hold three-dimensional (3D) magnetic resonance (MR) angiography of the renal arteries optimized with a 1-mL test bolus timing examination.
MATERIALS AND METHODS: Three-dimensional spoiled gradient-echo imaging (3.8-4.2/1.3-1.7 [repetition time msec/echo time msec], 25 degrees-40 degrees flip angle) was performed in 60 patients after administration of gadopentetate dimeglumine (average dose, 0.11 mmol/kg). Synchronization of contrast material administration with data acquisition was achieved with a 1-mL test dose of contrast material to estimate patient circulation parameters. Image quality was assessed by using contrast-to-noise (CNR), relative vascular enhancement, and venous-to-arterial enhancement ratios and subjective scoring of arterial and venous enhancement. The effect of the contrast material injection rate and the influence of breath holding during the timing examination also were examined.
RESULTS: Overall, of 60 studies, 58 were diagnostic and 56 demonstrated excellent arterial enhancement. Venous enhancement was seen in eight studies. The average aortic relative vascular enhancement (+/- SD) was 14.6 +/- 5.9, with an aorta-to-inferior vena cava (IVC) CNR of 69.7 +/- 43.9. The IVC-to-aorta venous-to-arterial enhancement ratio averaged 0.08 +/- 0.16. There was no significant difference in image quality based on injection rates or the performance of breath holding during the timing examination (P > .1).
CONCLUSION: Breath-hold gadolinium-enhanced renal MR angiography free of venous enhancement can be performed consistently and reliably with 20 mL of contrast material when studies are synchronized to patient circulation time by using a timing examination.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10189455     DOI: 10.1148/radiology.211.1.r99ap4869

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  4 in total

1.  Evaluation of renal arteries in living renal donors: comparison between MDCT angiography and gadolinium-enhanced 3D MR angiography.

Authors:  Tonsok Kim; Takamichi Murakami; Satoru Takahashi; Masatoshi Hori; Shirou Takahara; Naotsugu Ichimaru; Akihiko Okuyama; Yoshifumi Narumi; Hironobu Nakamura
Journal:  Radiat Med       Date:  2006-11-24

2.  [Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors].

Authors:  D Blondin; K Andersen; P Kroepil; M Cohnen; U Mödder; W Sandmann; K Ivens; G Jung
Journal:  Radiologe       Date:  2008-07       Impact factor: 0.635

3.  Comparing Diagnostic Techniques of Magnetic Resonance Angiography (MRA) and Doppler Ultrasonography in Determining Severity of Renal Artery Stenosis.

Authors:  Mohammad Hashemi Jazi; Mahfar Arasteh; Hamid Shamsolketabi; Aliakbar Tavassoli; Peyman Nilforoush; Mojgan Gharipour
Journal:  ARYA Atheroscler       Date:  2011

Review 4.  New magnetic resonance imaging methods in nephrology.

Authors:  Jeff L Zhang; Glen Morrell; Henry Rusinek; Eric E Sigmund; Hersh Chandarana; Lilach O Lerman; Pottumarthi V Prasad; David Niles; Nathan Artz; Sean Fain; Pierre-Hugues Vivier; Alfred K Cheung; Vivian S Lee
Journal:  Kidney Int       Date:  2013-09-25       Impact factor: 10.612

  4 in total