Literature DB >> 10188850

Sentinel node biopsy in 70 unselected patients with breast cancer: increased feasibility by using 10 mCi radiocolloid in combination with a blue dye tracer.

F W van der Ent1, R A Kengen, H A van der Pol, A G Hoofwijk.   

Abstract

AIMS: Lymphatic mapping and sentinel node (SN) biopsy in breast cancer contribute to more accurate staging, while using less invasive techniques. The aim of this study is to improve the accuracy and feasibility of this concept, increasing the identification rate of the SN, by using an alternative technique.
METHODS: In 70 unselected patients with primary breast cancer, of whom 51% had undergone previous excisional biopsy, lymphatic mapping was performed using 10 mCi (370 MBq) 99mTc-nanocolloid peritumorally, combined with an intradermal blue dye tracer.
RESULTS: Lymphoscintigraphy showed one or more SN in 97% and harvest of the SN was possible in all patients (identification rate 100%). Axillary metastases were found in 39%. Sensitivity of the SN biopsy was high, both after primary surgery (93%) and after previous surgery (100%). Internal mammary lymph node biopsy following lymphatic mapping was attempted in all 24 patients (34%) with parasternal SN visible on the scan and was successful in 15 patients, revealing metastatic involvement in five patients.
CONCLUSIONS: We conclude that SN biopsy, using a higher dose of peritumoral radiocolloid tracer, combined with intradermal blue dye tracer, increases feasibility in breast cancer, making this concept applicable for all patients with primary breast cancer.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10188850     DOI: 10.1053/ejso.1998.0594

Source DB:  PubMed          Journal:  Eur J Surg Oncol        ISSN: 0748-7983            Impact factor:   4.424


  15 in total

1.  Re: Chu et al "Do all patients with sentinel node metastasis from breast carcinoma need complete axillary node dissection?".

Authors:  F D Rahusen; S Meijer; P J van Diest
Journal:  Ann Surg       Date:  2000-04       Impact factor: 12.969

2.  Subdermal re-injection: a method to increase surgical detection of the sentinel node in breast cancer without increasing the false-negative rate.

Authors:  M T Bajén; A Benítez; J Mora; Y Ricart; N Ferran; S Guirao; D Carrera; M Gil; M J Pla; A Gumá; J A Palacin; J Martin-Comin
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-11-24       Impact factor: 9.236

Review 3.  The inextricable axis of targeted diagnostic imaging and therapy: An immunological natural history approach.

Authors:  Frederick O Cope; Bonnie Abbruzzese; James Sanders; Wendy Metz; Kristyn Sturms; David Ralph; Michael Blue; Jane Zhang; Paige Bracci; Wiam Bshara; Spencer Behr; Toby Maurer; Kenneth Williams; Joshua Walker; Allison Beverly; Brooke Blay; Anirudh Damughatla; Mark Larsen; Courtney Mountain; Erin Neylon; Kaeli Parcel; Kapil Raghuraman; Kevin Ricks; Lucas Rose; Akhilesh Sivakumar; Nicholas Streck; Bryan Wang; Christopher Wasco; Larry S Schlesinger; Abul Azad; Murugesan V S Rajaram; Wael Jarjour; Nicholas Young; Thomas Rosol; Amifred Williams; Michael McGrath
Journal:  Nucl Med Biol       Date:  2015-12-03       Impact factor: 2.408

4.  Impact of patient- and disease-specific factors on SLNB in breast cancer patients. Are current guidelines justified?

Authors:  A Bembenek; J Fischer; H Albrecht; E Kemnitz; S Gretschel; U Schneider; S Dresel; P M Schlag
Journal:  World J Surg       Date:  2007-02       Impact factor: 3.352

5.  Multicenter trial of sentinel node biopsy for breast cancer using both technetium sulfur colloid and isosulfan blue dye.

Authors:  L Tafra; D R Lannin; M S Swanson; K M Verbanac; A N Chua; P C Ng; M S Edwards; B E Halliday; C A Henry; L M Sommers; C M Carman; M R Molin; J E Yurko; R R Perry; R Williams
Journal:  Ann Surg       Date:  2001-01       Impact factor: 12.969

6.  Halsted revisited: internal mammary sentinel lymph node biopsy in breast cancer.

Authors:  F W van der Ent; R A Kengen; H A van der Pol; J A Povel; H J Stroeken; A G Hoofwijk
Journal:  Ann Surg       Date:  2001-07       Impact factor: 12.969

7.  [Sentinel lymph node biopsy in breast cancer].

Authors:  Gero Luschin
Journal:  Wien Med Wochenschr       Date:  2010-10-12

Review 8.  A comprehensive overview of radioguided surgery using gamma detection probe technology.

Authors:  Stephen P Povoski; Ryan L Neff; Cathy M Mojzisik; David M O'Malley; George H Hinkle; Nathan C Hall; Douglas A Murrey; Michael V Knopp; Edward W Martin
Journal:  World J Surg Oncol       Date:  2009-01-27       Impact factor: 2.754

9.  Comparison of vital dye-guided lymphatic mapping and dye plus gamma probe-guided sentinel node biopsy in breast cancer.

Authors:  Gábor Cserni; Mária Rajtár; Gábor Boross; Mária Sinkó; Mihály Svébis; Béla Baltás
Journal:  World J Surg       Date:  2002-03-01       Impact factor: 3.352

10.  Effect of increased (99m)Tc/(99)Tc ratios on count rates in sentinel node procedures: a randomised study.

Authors:  G M M Gommans; F M van der Zant; T G van der Schors; A van Dongen; G J J Teule; W W J Clarijs; B L A M Langenhorst; J W D de Waard
Journal:  Eur J Nucl Med Mol Imaging       Date:  2003-06-25       Impact factor: 9.236

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.