Literature DB >> 1017428

Technetium-99m-sulfur colloid. In vitro studies of various commercial kits.

O W Krogsgaard.   

Abstract

The quality of five commercial 99mTc-sulfur colloid kits was compared. A number of chemical parameters, which characterize the colloids, was used in order to study the influence of variations in the preparation procedures and storage of the final products. The differences between the kits could mainly be referred to the order of addition of the reagents. The quality was generally unaffected by variations in time-intervals during preparation. However, a certain heating time was necessary for optimal labeling. Variations in quantities of acid and buffer were found to influence the particle size as well as the content of unreacted pertechnetate. No deterioration in quality by storage was observed; on the contrary in some cases the content of free activity decreased.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1017428

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  4 in total

1.  A rapid and accurate method for sizing radiocolloids.

Authors:  M A Davis; A G Jones; H Trindade
Journal:  J Nucl Med       Date:  1974-11       Impact factor: 10.057

2.  Preparation of bolus 99m Tc-sulfur colloid.

Authors:  M L Sunderland; V A Brookeman
Journal:  J Nucl Med       Date:  1973-04       Impact factor: 10.057

3.  Technetium-99m sulfide colloid preparation for scintigraphy of the reticuloendothelial system.

Authors:  R Bertil; R Persson; Y Naversten
Journal:  Acta Radiol Ther Phys Biol       Date:  1970-12

4.  Preparation, distribution and utilization of technetium-99m-sulfur colloid.

Authors:  H S Stern; J G McAfee; G Subramanian
Journal:  J Nucl Med       Date:  1966-09       Impact factor: 10.057

  4 in total
  4 in total

1.  Measurement of colloid clearance rate as an adjunct to static liver imaging.

Authors:  J Miller; B L Diffey; J S Fleming
Journal:  Eur J Nucl Med       Date:  1979-02-01

2.  A computed tomography imaging-based subject-specific whole-lung deposition model.

Authors:  Xuan Zhang; Frank Li; Prathish K Rajaraman; Jiwoong Choi; Alejandro P Comellas; Eric A Hoffman; Benjamin M Smith; Ching-Long Lin
Journal:  Eur J Pharm Sci       Date:  2022-07-29       Impact factor: 5.112

3.  Factors affecting the quantitative liver-spleen scan in normal individuals.

Authors:  John C Hoefs; Muhammad Y Sheikh; Heather Guerrero; Norah Milne
Journal:  Dig Dis Sci       Date:  2005-02       Impact factor: 3.199

4.  99mTc-colloid kits from the view point of the accretion in the bone marrow--with special reference to comparison with 198Au-colloid.

Authors:  Y Ito; A Muranaka; K Nagai; N Otsuka; S Nishishita; M Uchida; T Kaji
Journal:  Eur J Nucl Med       Date:  1980-08
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.