Literature DB >> 10171978

Histological and histomorphometrical evaluation of the bone reaction to three different titanium alloy and hydroxyapatite coated implants.

J A Jansen1, J P van der Waerden, J G Wolke.   

Abstract

The aim of this study was to investigate the bone response to three different types of titanium (Ti) alloys and hydroxyapatite (HA) coated titanium alloy by histological and histomorphometrical analysis. Therefore, implants made of these materials were inserted into the tibia of rabbits. Implantation times were 6 and 16 weeks. The histological evaluation included measurement of the amount of bone apposition and analysis of the bone reaction and interface characteristics around the implants. The results demonstrated no marked differences in bony reaction to the different implant materials. In addition, the HA coatings showed loss of thickness.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 10171978     DOI: 10.1002/jab.770040302

Source DB:  PubMed          Journal:  J Appl Biomater        ISSN: 1045-4861


  2 in total

1.  An animal study on the bone behaviour of Ca-P-coated implants: influence of implant location.

Authors:  H Caulier; T Hayakawa; I Naert; J P Van Der Waerden; J G Wolke; J A Jansen
Journal:  J Mater Sci Mater Med       Date:  1997-09       Impact factor: 3.896

2.  Characterization of hydrothermally treated anodic oxides containing Ca and P on titanium.

Authors:  Xiaolong Zhu; Dong Whan Son; Joo L Ong; Kyohan Kim
Journal:  J Mater Sci Mater Med       Date:  2003-07       Impact factor: 3.896

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.