Literature DB >> 10171675

The effect of dissolution on plasma sprayed hydroxylapatite coatings on titanium.

R Y Whitehead1, L C Lucas, W R Lacefield.   

Abstract

Plasma sprayed hydroxylapatite (HA) coated titanium specimens were immersed into Ca-free Hank's balanced salt solution for periods of 1, 2, 4, and 6 weeks. At each of the respective time intervals the HA coatings were analyzed with X-ray diffraction (XRD), Fourier transform infrared spectroscopy (FTIR), and Raman spectroscopy to determine the effect of dissolution on the structure and composition of the coatings. At the 2- and 6-week intervals, additional samples were removed from solution and shear tested to evaluate the effect of dissolution on the coating-to-substrate interfacial bond strength. XRD results revealed that the plasma sprayed coatings retained their basic apatitic structure throughout the 6-week period in solution. There was, however, a trend towards a more definitive baseline, suggesting a loss of amorphous material by dissolution. FTIR and Raman analyses of the as-sprayed and dissolution specimens showed that the phosphate groups were not lost during the time in solution; however, there was a decrease in hydroxyl content as a result of dissolution mechanisms. FTIR also revealed an increase in carbonate content within the coating during immersion in the simulated physiological balanced salt solution. The average shear bond strengths for the as-sprayed, 2-, and 6-week dissolution specimens were 14.82+/-3.52 MPa, 12.51+/-3.41 MPa, and 12.54+/-2.02 MPa, respectively. Duncan's multiple range test confirmed that the shear bond strength was not significantly reduced after 6 weeks in solution, but there was evidence that suggested a decrease in interfacial bond strength as a result of dissolution mechanisms.

Entities:  

Mesh:

Substances:

Year:  1993        PMID: 10171675     DOI: 10.1016/0267-6605(93)90025-3

Source DB:  PubMed          Journal:  Clin Mater        ISSN: 0267-6605


  6 in total

1.  Development of porous spherical hydroxyapatite granules: application towards protein delivery.

Authors:  W Paul; C P Sharma
Journal:  J Mater Sci Mater Med       Date:  1999-07       Impact factor: 3.896

Review 2.  Nanotechnology approaches to improve dental implants.

Authors:  Antoni P Tomisa; Maximilien E Launey; Janice S Lee; Mahesh H Mankani; Ulrike G K Wegst; Eduardo Saiz
Journal:  Int J Oral Maxillofac Implants       Date:  2011       Impact factor: 2.804

3.  Randomized controlled clinical trial of 2 types of hydroxyapatite-coated implants on moderate periodontitis patients.

Authors:  Hyun-Suk Kim; Pil-Young Yun; Young-Kyun Kim
Journal:  J Periodontal Implant Sci       Date:  2016-10-18       Impact factor: 2.614

4.  Bone healing dynamics associated with 3 implants with different surfaces: histologic and histomorphometric analyses in dogs.

Authors:  Jungwon Lee; Jung Min Yoo; Heithem Ben Amara; Yong-Moo Lee; Young-Jun Lim; Haeyoung Kim; Ki-Tae Koo
Journal:  J Periodontal Implant Sci       Date:  2019-02-22       Impact factor: 2.614

5.  Effect of loading time on marginal bone loss around hydroxyapatite-coated implants.

Authors:  Young-Kyun Kim; Kyo-Jin Ahn; Pil-Young Yun; Minkyoung Kim; Hong-So Yang; Yang-Jin Yi; Ji-Hyun Bae
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2013-08-23

6.  Hydroxyapatite-coated implant: Clinical prognosis assessment via a retrospective follow-up study for the average of 3 years.

Authors:  Jun-Hong Jung; Sang-Yun Kim; Yang-Jin Yi; Bu-Kyu Lee; Young-Kyun Kim
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.