Recommendations on whole blood sampling, transport, and storage for simultaneous determination of pH, blood gases, and electrolytes. International Federation of Clinical Chemistry Scientific Division.

R W Burnett, A K Covington, N Fogh-Andersen, W R Külpman, A H Maas, O Müller-Plathe, O Siggaard-Andersen, A L Van Kessel, P D Wimberley, W G Zijlstra.   

Abstract

Pre-analytical variables, e.g., specimen collection, transport, and storage, can contribute significantly to inaccurate pH, blood gas, and electrolyte values. The International Federation of Clinical Chemistry (IFCC), through its Committee on pH, Blood Gases and Electrolytes, has developed specific recommendations to minimize the undesirable effects of pre-analytical variables. The Committee has drawn upon the experiences of its own members as well as published data by others. Specifically, the Committee has included pertinent guidelines and suggestions by the IFCC Working Group on Selective Electrodes (WGSE), the National Committee on Clinical Laboratory Standards (NCCLS), and the Electrolyte/Blood Gas Division of the American Association for Clinical Chemistry (AACC). This paper will familiarize the reader with the effect of different types of specimen containers and anticoagulants. It discusses important aspects of specimen collection procedures including patient status and special precautions during specimen collection from indwelling catheters or cannulae. The paper also identifies different requirements in storage and transport of specimens for blood gas and electrolyte analysis.

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 10155142

Source DB:  PubMed          Journal:  J Int Fed Clin Chem        ISSN: 1051-2292


  2 in total

1.  The glucose error in arterial sampling: assessing staff awareness and the effect of sampling technique.

Authors:  Vikesh Patel; Natalia Skorupska; Emily J Hodges; Mark C Blunt; Peter J Young; Maryanne Za Mariyaselvam
Journal:  J Intensive Care Soc       Date:  2020-10-28

2.  Glass syringes are better than plastic for preserving arterial blood gas for oxygen partial pressure determination: an explanation based on nanomaterial composition.

Authors:  Viroj Wiwanitkit
Journal:  Int J Nanomedicine       Date:  2006
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.