Literature DB >> 10150857

Pitfalls of automated perimetry in glaucoma diagnosis.

A Heijl, P Asman.   

Abstract

Perimetry is a cornerstone in glaucoma management. The detection of glaucomatous visual field loss is of crucial importance for diagnosing the disease. Automated threshold perimetry makes thorough testing of the central visual field very possible and high-quality data are often achieved. Certain factors, however, may hamper the visual field examination or visual field interpretation. Many diseases other than glaucoma are known to influence the visual field in more or less predictable ways. Of interest is also low patient reliability, learning and fatigue effects, as well as test artifacts and suboptimal test strategies or parameters. Finally, statistical aids provided by the built-in computer of the perimeter must be judged keeping in mind the population from which the patient is derived. We describe such pitfalls in glaucoma perimetry, how they can be identified, and dealt with clinically.

Entities:  

Mesh:

Year:  1995        PMID: 10150857     DOI: 10.1097/00055735-199504000-00008

Source DB:  PubMed          Journal:  Curr Opin Ophthalmol        ISSN: 1040-8738            Impact factor:   3.761


  4 in total

1.  Rationale and Development of an OCT-Based Method for Detection of Glaucomatous Optic Neuropathy.

Authors:  Jeffrey M Liebmann; Donald C Hood; Carlos Gustavo de Moraes; Dana M Blumberg; Noga Harizman; Yocheved S Kresch; Emmanouil Tsamis; George A Cioffi
Journal:  J Glaucoma       Date:  2022-02-28       Impact factor: 2.290

2.  A qualitative investigation into patients' views on visual field testing for glaucoma monitoring.

Authors:  Fiona C Glen; Helen Baker; David P Crabb
Journal:  BMJ Open       Date:  2014-01-10       Impact factor: 2.692

3.  New insights into measurement variability in glaucomatous visual fields from computer modelling.

Authors:  Richard A Russell; David F Garway-Heath; David P Crabb
Journal:  PLoS One       Date:  2013-12-30       Impact factor: 3.240

4.  Quality of care evaluation in non-functioning pituitary adenoma with chiasm compression: visual outcomes and timing of intervention clinical recommendations based on a systematic literature review and cohort study.

Authors:  Iris C M Pelsma; Marco J T Verstegen; Friso de Vries; Irene C Notting; Marike L D Broekman; Wouter R van Furth; Nienke R Biermasz; Alberto M Pereira
Journal:  Pituitary       Date:  2020-08       Impact factor: 4.107

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.