The effect of gamma irradiation on a xenograft tendon bioprosthesis.

S C Roe1, B K Milthorpe, K True, G J Rogers, K Schindhelm.   

Abstract

Radiation sterilisation of xenograft prostheses has been shown to cause damage to the material. Such damage has been imputed to affect the mechanical and biological properties and may contribute to long-term failure. This study has examined the effect of 25 kGy (2.5 Mrad) of gamma radiation on the mechanical and physicochemical properties and the biological function of a xenograft tendon bioprosthesis derived from glutaraldehyde cross-linked kangaroo tail tendon. The ultimate tensile stress of nonirradiated glutaraldehyde cross-linked tendon was greater than that of fresh frozen tendon, but irradiated cross-linked tendon did not differ. Irradiation did not alter the response to prolonged collagenase exposure. There was a decrease in overall apparent cross-link density (as determined by thermal denaturation temperature). After 12 months implantation, there was a slightly more active cellular response around irradiated tendon and the very peripheral fibres were infiltrated, but the mechanical properties of the retrieved implants were the same for irradiated and nonirradiated material. Gamma irradiation would appear to be a satisfactory method of sterilisation for glutaraldehyde cross-linked tendon materials. However, as damage to the cross-linked structure was detected in this study, it may not be appropriate in other applications.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 10149965     DOI: 10.1016/0267-6605(92)90094-a

Source DB:  PubMed          Journal:  Clin Mater        ISSN: 0267-6605


  5 in total

1.  [Validation of an automatic test system for sterile testing of amniotic membranes].

Authors:  H Thomasen; K-P Steuhl; D Meller
Journal:  Ophthalmologe       Date:  2014-05       Impact factor: 1.059

Review 2.  Relationship between tendon stiffness and failure: a metaanalysis.

Authors:  Andrew S LaCroix; Sarah E Duenwald-Kuehl; Roderic S Lakes; Ray Vanderby
Journal:  J Appl Physiol (1985)       Date:  2013-04-18

3.  Mechanical compromise of partially lacerated flexor tendons.

Authors:  Jaclyn Kondratko; Sarah Duenwald-Kuehl; Roderic Lakes; Ray Vanderby
Journal:  J Biomech Eng       Date:  2013-01       Impact factor: 2.097

Review 4.  Extracellular Matrix-Based Biomaterials for Cardiovascular Tissue Engineering.

Authors:  Astha Khanna; Maedeh Zamani; Ngan F Huang
Journal:  J Cardiovasc Dev Dis       Date:  2021-10-22

Review 5.  Rebuilding Tendons: A Concise Review on the Potential of Dermal Fibroblasts.

Authors:  Jin Chu; Ming Lu; Christian G Pfeifer; Volker Alt; Denitsa Docheva
Journal:  Cells       Date:  2020-09-08       Impact factor: 7.666

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.