Literature DB >> 10148978

Intra-aortic balloon counterpulsation support for elective coronary angioplasty in the setting of poor left ventricular function: a two center experience.

A Anwar1, M R Mooney, S H Stertzer, J F Mooney, R E Shaw, J D Madison, R A VanTassel, M C Murphy, R K Myler.   

Abstract

A two-center elective coronary angioplasty experience with intra-aortic balloon pump support for patients with severe left ventricular dysfunction is reported. To prevent hemodynamic collapse, an intra-aortic balloon pump was inserted percutaneously before coronary angioplasty in 97 patients with a left ventricular ejection fraction less than 35% (26% of whom had ejection fractions less than 25%). The cohort was predominantly male (71%) with a mean age of 64 +/- 9 years. Angioplasty was successfully performed in 83 (85.6%) patients and 80 (82.5%) of these successful patients were discharged from the hospital. Seven patients had unsuccessful angioplasty without a major cardiac event. Seven patients (7.2%) suffered a major cardiac event; 4 had emergent coronary bypass surgery with q-wave infarction, 2 had uneventful emergency coronary bypass surgery, and one patient died in the operating room after a failed angioplasty. Using logistic regression analysis, the presence of multivessel disease and a history of prior myocardial infarction were associated with more complications during angioplasty (p less than 0.05). Intra-aortic balloon pump placement did not interfere with the angioplasty procedure. Two patients had limb ischemia which resolved when the intra-aortic balloon pump was removed. Of the 80 successful patients discharged, 72 were followed for a mean of 22 months. At the latest follow-up, 52 had not suffered a myocardial infarction and were alive. Of the 20 late deaths, 16 were cardiac and 4 non-cardiac.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Year:  1990        PMID: 10148978

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  2 in total

1.  First-in-human experience with Aortix intraaortic pump.

Authors:  Amit N Vora; William Schuyler Jones; Adam D DeVore; Adrian Ebner; William Clifton; Manesh R Patel
Journal:  Catheter Cardiovasc Interv       Date:  2018-10-11       Impact factor: 2.692

2.  Survival of patients treated with intra-aortic balloon counterpulsation at a tertiary care center in Pakistan - patient characteristics and predictors of in-hospital mortality.

Authors:  Fahim H Jafary; Sohail A Khan; Haresh Kumar; Numaan F Malik; Khawar A Kazmi; Sajid Dhakam; Azam Shafquat; Aamir Hameed; Javed Tai; Najaf Nadeem
Journal:  BMC Cardiovasc Disord       Date:  2004-12-01       Impact factor: 2.298

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.