Literature DB >> 10148073

Heparin washout in the pediatric Cell Saver bowl.

J J Sistino1, D Owitz, L B Mongero.   

Abstract

The possibility of residual heparin in washed red cells transfused to neonatal or pediatric cardiac patients following bypass prompted a measurement of heparin concentrations. Samples were taken during 10 adult and 10 neonatal and pediatric bypass cases. Sample A was from the bypass circuit, Sample B from the Haemonetics Cell Saver bowl inlet before washing, Sample C from the Cell Saver bowl outlet after washing, and Sample D from the patient ten minutes after protamine. Heparin concentrations were measured by a chromogenic assay using activated Factor X. There was no significant difference between the adult and pediatric groups in the levels of heparin concentration on bypass, pre-washing and post-washing, and in the patients following protamine. In the pediatric group, only .002% of the pre-washed heparin remained after washing. This extremely low level of heparin (.0027 units/ml) is only 0.34 units in a 125 ml pediatric unit of Cell Saver blood. Based on post bypass patient samples, this has no clinical significance. Therefore, the Cell Saver can be used safely with neonates and pediatric patients without concern regarding residual heparin when properly processed.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 10148073

Source DB:  PubMed          Journal:  J Extra Corpor Technol        ISSN: 0022-1058


  6 in total

Review 1.  Clinical Utility of Autologous Salvaged Blood: a Review.

Authors:  Steven M Frank; Robert A Sikorski; Gerhardt Konig; Diamantis I Tsilimigras; Jan Hartmann; Mark A Popovsky; Timothy M Pawlik; Jonathan H Waters
Journal:  J Gastrointest Surg       Date:  2019-08-29       Impact factor: 3.452

2.  High-sensitivity to heparin associates with cell salvage transfusion in adolescent idiopathic scoliosis patient undergoing posterior spinal fusion.

Authors:  Li Du; Jianqiao Zheng; Yumin Tang
Journal:  Int J Clin Exp Med       Date:  2014-08-15

3.  Cell Saver Blood Reinfusion Up to 24 Hours Post Collection in Pediatric Cardiac Surgical Patients Does Not Increase Incidence of Hospital-Acquired Infections or Mortality.

Authors:  Laura Boulos; Joseph D Kuebler; Ron Angona; Dawn Sweeney; Hongyue Wang; Elizabeth Nocera; Jill M Cholette
Journal:  J Extra Corpor Technol       Date:  2021-09

4.  Application of the continuous autotransfusion system (CATS) to prevent transfusion-related hyperkalemia following hyperkalemic cardiac arrest in an infant -A case report-.

Authors:  Hye-Min Sohn; Yong-Hee Park; Hyo-Jin Byon; Jin-Tae Kim; Hee-Soo Kim; Chong Sung Kim
Journal:  Korean J Anesthesiol       Date:  2012-03-21

5.  Argatroban for anticoagulation of a blood salvage system - an ex-vivo study.

Authors:  Martin Beiderlinden; Carsten Brau; Santo di Grazia; Michael Wehmeier; Tanja A Treschan
Journal:  BMC Anesthesiol       Date:  2016-07-15       Impact factor: 2.217

6.  Coagulopathy associated with cell salvage transfusion following cerebrovascular surgery.

Authors:  Jianqiao Zheng; Li Du; Guizhi Du; Bin Liu
Journal:  Pak J Med Sci       Date:  2013-11       Impact factor: 1.088

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.