Literature DB >> 10147875

Power and time requirements for use of the argon laser to polymerize composite resins.

W P Kelsey1, R J Blankenau, G L Powell, W W Barkmeier, E F Stormberg.   

Abstract

A carefully controlled laboratory study was conducted to determine the optimum power setting and polymerization cycle time to cure four commercially available composite resins with an argon laser. Most effective resin polymerization was achieved when Prisma APH was polymerized at 310 mW for 7 seconds, when Herculite was polymerized at 160 mW for 12 seconds, when P-50 was polymerized at 525 mW for 13 seconds and when Silux Plus was polymerized at 270 mW for 13 seconds. The exact parameters of laser power and exposure time seem to be material specific, with greater variation being noted in power setting than in exposure time.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 10147875     DOI: 10.1089/clm.1992.10.273

Source DB:  PubMed          Journal:  J Clin Laser Med Surg        ISSN: 1044-5471


  6 in total

1.  Argon ion laser curing depth effect on a composite resin.

Authors:  Míriam Lacalle Turbino; Luis Carlos Belan; Valéria Soprano; Kátia Martis Rode; Patrícia Ramos Lloret; Michel Nicolau Youssef
Journal:  Lasers Med Sci       Date:  2010-05-28       Impact factor: 3.161

2.  Comparison of microleakages of photo-cured composites using three different light sources: halogen lamp, LED and argon laser: an in vitro study.

Authors:  M Tielemans; Ph Compere; S O Geerts; M Lamy; M Limme; R J G De Moor; K I M Delmé; M F Bertrand; E Rompen; S Nammour
Journal:  Lasers Med Sci       Date:  2007-11-24       Impact factor: 3.161

3.  The applicability of DPSS laser for light curing of composite resins.

Authors:  Yong Hoon Kwon; Chang-Min Jang; Dong-Hee Shin; Hyo-Joung Seol; Hyung-Il Kim
Journal:  Lasers Med Sci       Date:  2007-09-28       Impact factor: 3.161

4.  Light-curing of dental resins with GaN violet laser diode: the effect of photoinitiator on mechanical strength.

Authors:  Atsushi Kameyama; Hitoshi Hatayama; Junji Kato; Akiko Haruyama; Hiromi Teraoka; Yasuaki Takase; Masao Yoshinari; Masatake Tsunoda
Journal:  Lasers Med Sci       Date:  2011-02-23       Impact factor: 3.161

5.  Argon Ion Laser Polymerized Acrylic Resin: A Comparative Analysis of Mechanical Properties of Laser Cured, Light Cured and Heat Cured Denture Base Resins.

Authors:  S Srinivasa Murthy; Gargi S Murthy
Journal:  J Int Oral Health       Date:  2015-06

6.  In vitro Study - Comparative Evaluation of Bond Strengths of Stainless Steel Brackets and Ceramic Brackets after Curing with the Argon Laser and the Conventional Visible Light.

Authors:  Priya Kalidass; Karthiga Mohankumar; Preethi Murali; Harish Ponniah; S Srinidhi; K A Vigneshwaran; Bhuvaneswari Mani
Journal:  J Pharm Bioallied Sci       Date:  2022-07-13
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.