Polyethylene wear debris and tissue reactions in knee as compared to hip replacement prostheses.

T P Schmalzried1, M Jasty, A Rosenberg, W H Harris.   

Abstract

Differences in bearing surface conformity and wear mechanisms suggest that the polyethylene (PE) wear debris generated by total knee replacement (TKR) prostheses should be different than that in total hip replacement prostheses (THR). To address this issue, PE wear debris and the cellular response in periprosthetic tissues from 19 failed TKRs was compared to that from 24 failed THRs using polarized light microscopy and a semiquantitative grading system. The foreign-body inflammatory reaction in the THR case was characterized by plump macrophages with a diffuse cytoplasmic birefringence when examined under polarized light, indicating the presence of multiple submicron particles of PE. The majority of PE particles were less than 1 mum in size and only a small fraction of the total were greater than 10 mum. The foreign-body inflammatory reaction in the TKR cases was characterized by giant cells with fewer macrophages. In the TKR specimens, the size range of PE particles was broader than in the hips. PE particles between 2 and 20 mum were frequent in TKR specimens; particles less than 1 mum in length were less common than in the THR specimens. Diffuse cytoplasmic birefringence was not a characteristic of the TKR cases. These histologic differences were so consistently distinct that the source of the specimen (i.e., from a THR or TKR) could be blindly determined by light microscopy.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1994        PMID: 10147443     DOI: 10.1002/jab.770050302

Source DB:  PubMed          Journal:  J Appl Biomater        ISSN: 1045-4861


  11 in total

1.  Comparison of the response of three human monocytic cell lines to challenge with polyethylene particles of known size and dose.

Authors:  J B Matthews; T R Green; M H Stone; B M Wroblewski; J Fisher; E Ingham
Journal:  J Mater Sci Mater Med       Date:  2001-03       Impact factor: 3.896

2.  Knee wear measured in retrievals: a polished tray reduces insert wear.

Authors:  Daniel J Berry; John H Currier; Michael B Mayor; John P Collier
Journal:  Clin Orthop Relat Res       Date:  2012-07       Impact factor: 4.176

3.  Highly crosslinked polyethylene is safe for use in total knee arthroplasty.

Authors:  Jeffrey T Hodrick; Erik P Severson; Deborah S McAlister; Brian Dahl; Aaron A Hofmann
Journal:  Clin Orthop Relat Res       Date:  2008-09-10       Impact factor: 4.176

4.  Does increased topside conformity in modular total knee arthroplasty lead to increased backside wear?

Authors:  Ran Schwarzkopf; Richard D Scott; Evan M Carlson; John H Currier
Journal:  Clin Orthop Relat Res       Date:  2015-01       Impact factor: 4.176

5.  Peri-Implant Distribution of Polyethylene Debris in Postmortem-Retrieved Knee Arthroplasties: Can Polyethylene Debris Explain Loss of Cement-Bone Interlock in Successful Total Knee Arthroplasties?

Authors:  Karen I Cyndari; Jacklyn R Goodheart; Mark A Miller; Megan E Oest; Timothy A Damron; Kenneth A Mann
Journal:  J Arthroplasty       Date:  2017-02-03       Impact factor: 4.757

Review 6.  Polyethylene in knee arthroplasty: A review.

Authors:  Gautam Chakrabarty; Mayank Vashishtha; Daniel Leeder
Journal:  J Clin Orthop Trauma       Date:  2015-02-19

7.  Are periprosthetic tissue reactions observed after revision of total disc replacement comparable to the reactions observed after total hip or knee revision surgery?

Authors:  Ilona M Punt; Shennah Austen; Jack P M Cleutjens; Steven M Kurtz; René H M ten Broeke; Lodewijk W van Rhijn; Paul C Willems; André van Ooij
Journal:  Spine (Phila Pa 1976)       Date:  2012-01-15       Impact factor: 3.468

8.  Changes in microgaps, micromotion, and trabecular strain from interlocked cement-trabecular bone interfaces in total knee replacements with in vivo service.

Authors:  Mark A Miller; Jacklyn R Goodheart; Benjamin Khechen; Dennis Janssen; Kenneth A Mann
Journal:  J Orthop Res       Date:  2015-12-10       Impact factor: 3.494

9.  Polyethylene and cobalt-chromium molybdenium particles elicit a different immune response in vitro.

Authors:  Stefan Endres; Ingo Bartsch; Sebastian Stürz; Marita Kratz; Axel Wilke
Journal:  J Mater Sci Mater Med       Date:  2007-08-15       Impact factor: 3.896

10.  Simultaneous Characterization of Implant Wear and Tribocorrosion Debris within Its Corresponding Tissue Response Using Infrared Chemical Imaging.

Authors:  Songyun Liu; Deborah J Hall; Craig J Della Valle; Michael J Walsh; Joshua J Jacobs; Robin Pourzal
Journal:  Biotribology (Oxf)       Date:  2021-02-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.