An evaluation of MDI (metered dose inhaler) spacers and adapters: their effect on the respirable volume of medication.

J Ebert1, A B Adams, B Green-Eide.   

Abstract

The use of a metered dose inhaler (MDI) with an adapter or spacer designed to deliver medication to ventilated patients has been found to produce effects similar to those achieved with small volume nebulizers. For 9 commonly used MDI adapters or spacers, we measured and compared their production of available respirable volume (ARV) of medication. A simulated ventilator circuit was configured to determine ARV as measured by a laser particle-size counter. The adapters or spacers were grouped in three categories: chamber, in-line, and elbow styles. The devices were actuated into the circuit, and ARV was measured 36 separate times with various combinations of medication and medication canister. We found significant differences in ARV between devices, device categories, and medications as compared by ANOVA testing. In this study, chamber-style MDI devices produced greater respirable volume than the in-line- or the elbow-style devices. Of the chamber-style devices, the cone-shaped chamber device provided more respirable volume than did the other two chamber devices. We also found differences among the medications, although we did not anticipate such differences. The possible factors to explain medication differences were not investigated in this study. Because ARV differs according to the design of the individual device used, the choice of device may alter the respirable volume of the medication delivered and, therefore, the effectiveness of the prescribed medication. We conclude that to achieve the desired effects of the medication, practitioners may need to customize the number of MDI actuations according to the device in use.

Entities:  

Mesh:

Substances:

Year:  1992        PMID: 10145777

Source DB:  PubMed          Journal:  Respir Care        ISSN: 0020-1324            Impact factor:   2.258


  2 in total

Review 1.  The delivery of aerosolized steroids from MDIs with nozzle extensions: quantitative laboratory evaluation of a method to improve aerosol delivery to intubated patients.

Authors:  D Hess; D Fisher; R A Peterfreund; R M Kacmarek
Journal:  Intensive Care Med       Date:  1995-11       Impact factor: 17.440

Review 2.  Bronchodilator delivery with metered-dose inhaler during mechanical ventilation.

Authors:  D Georgopoulos; E Mouloudi; E Kondili; M Klimathianaki
Journal:  Crit Care       Date:  2000-07-11       Impact factor: 9.097

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.