| Literature DB >> 1014040 |
J R Antunes, S L Dale, J C Melby.
Abstract
A simplified, non-chromatographic method for aldosterone-gamma-lactone (2) radio-immunoassay is described, using a high titer aldosterone-gamma-lactone antibody. This method takes six working hours for completion; the blanks are below the sensitivity of the assay (0-10 pg), and the intra and interassay coefficient of variation is 4.9% and 8.2% respectively. There is no significant variation with different plasma volumes assayed and the plot of added and assayed aldosterone gives a slope of 0.983. The negligible cross reactivity with other steroids and lactones eliminates the problem of interference by these substances.Entities:
Mesh:
Substances:
Year: 1976 PMID: 1014040 DOI: 10.1016/0039-128x(76)90004-0