Surface ultrastructure of silicone rubber aortic valve poppetts after long-term implantation. A scanning electron microscope study of four poppets.

S P Allwork, R Norton.   

Abstract

The surface ultrastructure, demonstrated by scanning electron microscopy, is described in four implanted Silastic aortic valve poppets. Ball variance was discovered at necropsy in two patients and clinically in one in whom the poppet was replaced. The fourth patient underwent reoperation, but ball variance was neither suspected nor found. All four poppets were densely coated with biological debris and microthrombi. The 'coat' was soluble in a weak solution of sodium hydroxide. The true Silastic surface beneath the coat was little altered compared with unimplanted poppets, even after 10 years' implantation.

Entities:  

Mesh:

Substances:

Year:  1976        PMID: 1013945      PMCID: PMC470505          DOI: 10.1136/thx.31.6.742

Source DB:  PubMed          Journal:  Thorax        ISSN: 0040-6376            Impact factor:   9.139


  18 in total

1.  DEATH DUE TO MIGRATION OF THE BALL FROM AN AORTIC-VALVE PROSTHESIS.

Authors:  A KROSNICK
Journal:  JAMA       Date:  1965-03-29       Impact factor: 56.272

2.  Current status of prosthetics for heart valve replacement.

Authors:  D M Behrendt; W G Austen
Journal:  Prog Cardiovasc Dis       Date:  1973 Jan-Feb       Impact factor: 8.194

3.  Resolution and organization of platelet-rich mural thrombi in carotid arteries of swine.

Authors:  L Jorgensen; H C Rowsell; T Hovig; J F Mustard
Journal:  Am J Pathol       Date:  1967-11       Impact factor: 4.307

4.  Death due to swelling of ball component of aortic ball-value prosthesis.

Authors:  E G Laforet
Journal:  N Engl J Med       Date:  1967-05-04       Impact factor: 91.245

5.  Electron microscopy and physical chemistry of healing in prosthetic heart valves, skirts, and struts. Modification by electrochemically clean physiologic surfaces.

Authors:  P N Sawyer; B Stanczewski; S Srinivasan; J G Stempak; G W Kammlott
Journal:  J Thorac Cardiovasc Surg       Date:  1974-01       Impact factor: 5.209

6.  Aortic ball degeneration with splenic rupture.

Authors:  H H Kloth; M Spagnuolo
Journal:  N Y State J Med       Date:  1972-11-01

7.  Detection of ball variance in prosthetic heart valves by liver biopsy.

Authors:  R L Ridolfi; G M Hutchins
Journal:  Johns Hopkins Med J       Date:  1974-03

Review 8.  Thromboembolism: a manifestation of the response of blood to injury.

Authors:  J F Mustard; M A Packham
Journal:  Circulation       Date:  1970-07       Impact factor: 29.690

9.  Thrombo-embolic complications of the cloth-covered Starr-Edwards prostheses No. 2300 aortic and No. 6300 mitral.

Authors:  J Cleland; P J Molloy
Journal:  Thorax       Date:  1973-01       Impact factor: 9.139

10.  Changes in the durability of silicone rubber in ball-valve prostheses.

Authors:  J C Hylen; R P Hodam; F E Kloster
Journal:  Ann Thorac Surg       Date:  1972-04       Impact factor: 4.330

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.