Literature DB >> 10101838

Detecting staphylococcal enterotoxin B using an automated fiber optic biosensor.

K D King1, G P Anderson, K E Bullock, M J Regina, E W Saaski, F S Ligler.   

Abstract

The Man-portable Analyte Identification System (MANTIS), the first fully automated, self-contained, portable fiber optic biosensor, was utilized for the detection of Staphylococcal Enterotoxin B (SEB), a bacterial toxin produced by Staphylococcus aureus that commonly causes food poisoning. Because of its remarkable toxicity and stability, SEB is considered a prime threat as a biological weapon of mass destruction. The assay for SEB was used to evaluate the MANTIS' ability to function in the presence of various environmental interferents. The sensor could reliably detect SEB spiked into liquid samples containing a variety of smoke particles. However, substantial interference occurred when SEB was mixed into matrices capable of adsorbing SEB, such as 1% solutions of clay, topsoil, or pollen. Of equal importance, none of the interferents produced false positives in the MANTIS. The MANTIS demonstrated the capability to perform simultaneous immunoassays rapidly in the field with little or no user intervention.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10101838     DOI: 10.1016/s0956-5663(98)00108-0

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  5 in total

Review 1.  Current and developing technologies for monitoring agents of bioterrorism and biowarfare.

Authors:  Daniel V Lim; Joyce M Simpson; Elizabeth A Kearns; Marianne F Kramer
Journal:  Clin Microbiol Rev       Date:  2005-10       Impact factor: 26.132

2.  Development of combination tapered fiber-optic biosensor dip probe for quantitative estimation of interleukin-6 in serum samples.

Authors:  Chun Wei Wang; Upender Manne; Vishnu B Reddy; Denise K Oelschlager; Venkat R Katkoori; William E Grizzle; Rakesh Kapoor
Journal:  J Biomed Opt       Date:  2010 Nov-Dec       Impact factor: 3.170

3.  Coupling immunomagnetic separation on magnetic beads with matrix-assisted laser desorption ionization-time of flight mass spectrometry for detection of staphylococcal enterotoxin B.

Authors:  Gitta Schlosser; Petr Kacer; Marek Kuzma; Zoltán Szilágyi; Alida Sorrentino; Carla Manzo; Rosa Pizzano; Livia Malorni; Gabriella Pocsfalvi
Journal:  Appl Environ Microbiol       Date:  2007-09-07       Impact factor: 4.792

4.  Prevalence, Virulence Genes, Antimicrobial Susceptibility, and Genetic Diversity of Staphylococcus aureus from Retail Aquatic Products in China.

Authors:  Dongli Rong; Qingping Wu; Mingfang Xu; Jumei Zhang; Shubo Yu
Journal:  Front Microbiol       Date:  2017-04-20       Impact factor: 5.640

5.  Selection of staphylococcal enterotoxin B (SEB)-binding peptide using phage display technology.

Authors:  Esra Acar Soykut; Fahriye Ceyda Dudak; Ismail Hakki Boyaci
Journal:  Biochem Biophys Res Commun       Date:  2008-03-24       Impact factor: 3.575

  5 in total