Literature DB >> 10094885

99m-Tc-tetrofosmin scintigraphy and breast cancer.

P Berghammer1, R Obwegeser, S Mülauer-Ertl, G Karanikas, C Wiltschke, E Kubista, H Sinzinger, C Zielinski.   

Abstract

BACKGROUND: 99m-Tc-tetrofosmin holds significant interest among medical oncologists because of its high positive predictive value (>90%) in pilot trials, exceeding sensitivity and specificity rates of mammography. Objective. Our objective was to assess the diagnostic accuracy of 99m-Tc-tetrofosmin whole-body scintigraphy in outpatients. PATIENTS AND METHODS: Thirty-one patients with an abnormal mammograph (n = 22) or follow-up patients (n = 9), 7 of whom were known to have metastatic disease, were included. Tracer (550 MBq) was injected into the cubital vein. Whole-body planar and single photon emission computed tomography images of regions of interest were obtained. Histology, computed tomography (CT), or magnetic resonance imaging (MRI) were performed to confirm scintigraphic results. Correlation between scintigraphy and CT or MRI was assessed by two independent radiologists. Accuracy, sensitivity, and specificity rates for the diagnosis of local and distant breast cancer lesions were given.
RESULTS: Of the 22 first-visit patients, 15 had breast cancer, and 7 had no evidence of any malignant disease. Of all patients examined (n = 31), 21 had distant metastases. Breast tumors were correctly diagnosed in 14/15 patients (93%), with only 1 false-negative result. Extrahepatic metastatic lesions (n = 16) were correctly diagnosed in 14 (88%) patients, whereas the method was not suitable for the diagnosis of liver metastases.
CONCLUSION: Tetrofosmin scintigraphy has shown very high detection rates of breast tumors and of metastatic lesions and is therefore a valuable option in breast cancer diagnosis. Copyright 1999 Academic Press.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10094885     DOI: 10.1006/gyno.1998.5310

Source DB:  PubMed          Journal:  Gynecol Oncol        ISSN: 0090-8258            Impact factor:   5.482


  2 in total

1.  99mTc glucarate high-resolution imaging of drug sensitive and drug resistant human breast cancer xenografts in SCID mice.

Authors:  Zhonglin Liu; Gail D Stevenson; Harrison H Barrett; George A Kastis; Michel Bettan; Lars R Furenlid; Donald W Wilson; James M Woolfenden; Koon Yan Pak
Journal:  Nucl Med Commun       Date:  2004-07       Impact factor: 1.690

2.  Noncardiac findings on dual-isotope myocardial perfusion SPECT.

Authors:  Kim A Williams; Kalisha A Hill; Candace M Sheridan
Journal:  J Nucl Cardiol       Date:  2003 Jul-Aug       Impact factor: 5.952

  2 in total