Literature DB >> 10093803

Results of the Bosworth method for unstable fractures of the distal clavicle.

H Yamaguchi1, H Arakawa, M Kobayashi.   

Abstract

Eleven consecutive Neer's type II unstable fractures of the distal third of the clavicle were treated by open reduction and internal fixation, using a temporary Bosworth-type screw. In all cases, fracture healing occurred within 10 weeks. Shoulder function was restored to the pre-injury level. A Bosworth-type screw fixation is a relatively easy and safe technique of open reduction and internal fixation of type II fractures of the distal third of the clavicle.

Entities:  

Mesh:

Year:  1998        PMID: 10093803      PMCID: PMC3619681          DOI: 10.1007/s002640050279

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  22 in total

Review 1.  Clavicle and acromioclavicular joint injuries: a review of imaging, treatment, and complications.

Authors:  Yulia Melenevsky; Corrie M Yablon; Arun Ramappa; Mary G Hochman
Journal:  Skeletal Radiol       Date:  2010-06-06       Impact factor: 2.199

Review 2.  Comparison of the efficacy of a distal clavicular locking plate versus a clavicular hook plate in the treatment of unstable distal clavicle fractures and a systematic literature review.

Authors:  Chunlin Zhang; Junwu Huang; Yi Luo; Hua Sun
Journal:  Int Orthop       Date:  2014-04-15       Impact factor: 3.075

3.  Open reduction and fixation of displaced lateral clavicle fractures using the Minimally Invasive Acromioclavicular Joint Reconstruction (MINAR®) technique: a case series review.

Authors:  Peter Kenyon; Barnes William Morgan; Mark Webb; Darren Ebreo; Andrew Wheelton; Matt John Ravenscroft
Journal:  Shoulder Elbow       Date:  2014-05-27

4.  Modified tension band for displaced type 2 lateral end clavicle fractures.

Authors:  Laxman Rijal; Gopal Sagar; Anshumala Joshi; Khima Nand Joshi
Journal:  Int Orthop       Date:  2012-03-06       Impact factor: 3.075

5.  Precontoured superior locked plating of distal clavicle fractures: a new strategy.

Authors:  Jaron R Andersen; Matt P Willis; Ryan Nelson; Mark A Mighell
Journal:  Clin Orthop Relat Res       Date:  2011-12       Impact factor: 4.176

6.  Arthroscopic-assisted locking compression plate clavicular hook fixation for unstable fractures of the lateral end of the clavicle: a prospective study.

Authors:  Kwang Won Lee; Sang Ki Lee; Kap Jung Kim; Yong In Kim; Won Cho Kwon; Won Sik Choy
Journal:  Int Orthop       Date:  2009-12-09       Impact factor: 3.075

7.  Treatment of unstable distal third clavicular fracture with locked distal radius plate.

Authors:  Ashraf Abdeldayem; Waleed Nafea; Abdelsalam Eid
Journal:  J Orthop       Date:  2013-11-20

Review 8.  Hook plate fixation of acute displaced lateral clavicle fractures: mid-term results and a brief literature overview.

Authors:  Davut Tiren; Alexander J M van Bemmel; Dingeman J Swank; Frits M van der Linden
Journal:  J Orthop Surg Res       Date:  2012-01-11       Impact factor: 2.359

9.  Comparison of the efficacy of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle.

Authors:  Yih-Shiunn Lee; Ming-Jye Lau; Ya-Chun Tseng; Wen-Chiao Chen; Hsin-Yi Kao; Jyh-Ding Wei
Journal:  Int Orthop       Date:  2008-12-03       Impact factor: 3.075

10.  Evaluation of the use of the hook plate in Neer type 2 lateral clavicle fractures and Rockwood types 3-5 acromioclavicular joint dislocations.

Authors:  C C Drijfhout van Hooff; R Haverlag; W J Willems
Journal:  Eur J Trauma Emerg Surg       Date:  2013-06-27       Impact factor: 3.693

View more