Literature DB >> 10090636

Exercise-induced hypoxaemia in highly trained cyclists at 40% peak oxygen uptake.

A J Rice1, G C Scroop, C J Gore, A T Thornton, M A Chapman, H W Greville, M D Holmes, R Scicchitano.   

Abstract

A group of 15 competitive male cyclists [mean peak oxygen uptake, VO2peak 68.5 (SEM 1.5 ml x kg(-1) x min(-1))] exercised on a cycle ergometer in a protocol which began at an intensity of 150 W and was increased by 25 W every 2 min until the subject was exhausted. Blood samples were taken from the radial artery at the end of each exercise intensity to determine the partial pressures of blood gases and oxyhaemoglobin saturation (SaO2), with all values corrected for rectal temperature. The SaO2 was also monitored continuously by ear oximetry. A significant decrease in the partial pressure of oxygen in arterial blood (PaO2) was seen at the first exercise intensity (150 W, about 40% VO2peak). A further significant decrease in PaO2 occurred at 200 W, whereafter it remained stable but still significantly below the values at rest, with the lowest value being measured at 350 W [87.0 (SEM 1.9) mmHg]. The partial pressure of carbon dioxide in arterial blood (PaCO2) was unchanged up to an exercise intensity of 250 W whereafter it exhibited a significant downward trend to reach its lowest value at an exercise intensity of 375 W [34.5 (SEM 0.5) mmHg]. During both the first (150 W) and final exercise intensities (VO2peak) PaO2 was correlated significantly with both partial pressure of oxygen in alveolar gas (P(A)O2, r = 0.81 and r = 0.70, respectively) and alveolar-arterial difference in oxygen partial pressure (P(A-a)O2, r = 0.63 and r = 0.86, respectively) but not with PaCO2. At VO2peak PaO2 was significantly correlated with the ventilatory equivalents for both oxygen uptake and carbon dioxide output (r = 0.58 and r = 0.53, respectively). When both P(A)O2 and P(A-a)O2 were combined in a multiple linear regression model, at least 95% of the variance in PaO2 could be explained at both 150 W and VO2peak. A significant downward trend in SaO2 was seen with increasing exercise intensity with the lowest value at 375 W [94.6 (SEM 0.3)%]. Oximetry estimates of SaO2 were significantly higher than blood measurements at all times throughout exercise and no significant decrease from rest was seen until 350 W. The significant correlations between PaO2 and P(A)O2 with the first exercise intensity and at VO2peak led to the conclusion that inadequate hyperventilation is a major contributor to exercise-induced hypoxaemia.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10090636     DOI: 10.1007/s004210050520

Source DB:  PubMed          Journal:  Eur J Appl Physiol Occup Physiol        ISSN: 0301-5548


  9 in total

Review 1.  Exercise-induced arterial hypoxaemia in athletes: a review.

Authors:  C Prefaut; F Durand; P Mucci; C Caillaud
Journal:  Sports Med       Date:  2000-07       Impact factor: 11.136

2.  Hypoxic ventilatory response is correlated with increased submaximal exercise ventilation after live high, train low.

Authors:  Nathan E Townsend; Christopher J Gore; Allan G Hahn; Robert J Aughey; Sally A Clark; Tahnee A Kinsman; Michael J McKenna; John A Hawley; Chin-Moi Chow
Journal:  Eur J Appl Physiol       Date:  2004-12-18       Impact factor: 3.078

Review 3.  Red blood cell volume and the capacity for exercise at moderate to high altitude.

Authors:  Robert A Jacobs; Carsten Lundby; Paul Robach; Max Gassmann
Journal:  Sports Med       Date:  2012-08-01       Impact factor: 11.136

4.  Exercise-induced arterial hypoxaemia and the mechanics of breathing in healthy young women.

Authors:  Paolo B Dominelli; Glen E Foster; Giulio S Dominelli; William R Henderson; Michael S Koehle; Donald C McKenzie; A William Sheel
Journal:  J Physiol       Date:  2013-04-15       Impact factor: 5.182

5.  The effect of exercise-induced hypoxemia on blood redox status in well-trained rowers.

Authors:  Antonios Kyparos; Christos Riganas; Michalis G Nikolaidis; Michalis Sampanis; Maria D Koskolou; Gerasimos V Grivas; Dimitrios Kouretas; Ioannis S Vrabas
Journal:  Eur J Appl Physiol       Date:  2011-09-27       Impact factor: 3.078

6.  Inspiratory muscle warm-up does not improve cycling time-trial performance.

Authors:  M A Johnson; I R Gregson; D E Mills; J T Gonzalez; G R Sharpe
Journal:  Eur J Appl Physiol       Date:  2014-05-31       Impact factor: 3.078

7.  Cardiopulmonary Exercise Testing in Athletes: Expect the Unexpected.

Authors:  Bradley J Petek; Sarah K Gustus; Meagan M Wasfy
Journal:  Curr Treat Options Cardiovasc Med       Date:  2021-05-12

8.  Sex differences in respiratory exercise physiology.

Authors:  A William Sheel; Jennifer C Richards; Glen E Foster; Jordan A Guenette
Journal:  Sports Med       Date:  2004       Impact factor: 11.136

Review 9.  Pulmonary gas exchange and acid-base balance during exercise.

Authors:  Michael K Stickland; Michael I Lindinger; I Mark Olfert; George J F Heigenhauser; Susan R Hopkins
Journal:  Compr Physiol       Date:  2013-04       Impact factor: 9.090

  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.