Literature DB >> 10090601

Pitfalls in the use of spiral CT for identification of intracranial aneurysms.

N Young1, N W Dorsch, R J Kingston.   

Abstract

We describe problems encountered in our first 136 patients, with 95 aneurysms, who underwent spiral CT for investigation of possible aneurysms involving the circle of Willis and adjacent major vessels, and who had surgical and/or angiographic confirmation. There were seven false-positive cases, of which the first three could be explained by operator inexperience. There were four false negatives, all small aneurysms; two were not seen because of operator error and two were hidden by an adjacent larger aneurysm. Clip artefacts prevented diagnostic studies in six of 21 postoperative studies. One aneurysm was outside the CT field of view, being on a pericallosal artery. One basilar artery tip aneurysm was excluded from the field of the CT study because of a planning error. Inspection of the axial source images is critical if the diagnosis of small or thrombosed aneurysms is to be made. Close attention to image acquisition and computer modelling is required to reduce errors in spiral CT angiography of intracranial aneurysms.

Entities:  

Mesh:

Year:  1999        PMID: 10090601     DOI: 10.1007/s002340050712

Source DB:  PubMed          Journal:  Neuroradiology        ISSN: 0028-3940            Impact factor:   2.804


  4 in total

1.  Role of neuroradiology in evaluating cerebral aneurysms.

Authors:  A Stafa; M Leonardi
Journal:  Interv Neuroradiol       Date:  2008-10-09       Impact factor: 1.610

2.  Detection and characterization of very small cerebral aneurysms by using 2D and 3D helical CT angiography.

Authors:  J Pablo Villablanca; Reza Jahan; Parizad Hooshi; Silvester Lim; Gary Duckwiler; Aman Patel; James Sayre; Neil Martin; John Frazee; John Bentson; Fernando Viñuela
Journal:  AJNR Am J Neuroradiol       Date:  2002-08       Impact factor: 3.825

3.  Effective coil embolization of intracavernous carotid artery pseudoaneurysm with parental artery preservation following severe head trauma in a pediatric patient.

Authors:  Kinda Altali; Luis Arruza; Luis López-Ibor; Esther Aleo
Journal:  Childs Nerv Syst       Date:  2013-11-06       Impact factor: 1.475

4.  Multislice CT angiography in the selection of patients with ruptured intracranial aneurysms suitable for clipping or coiling.

Authors:  H E Westerlaan; J Gravendeel; D Fiore; J D M Metzemaekers; R J M Groen; J J A Mooij; M Oudkerk
Journal:  Neuroradiology       Date:  2007-09-22       Impact factor: 2.804

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.