Literature DB >> 10086963

Mechanisms of death in the CABG Patch trial: a randomized trial of implantable cardiac defibrillator prophylaxis in patients at high risk of death after coronary artery bypass graft surgery.

J T Bigger1, W Whang, J N Rottman, R E Kleiger, C D Gottlieb, P B Namerow, R C Steinman, N A Estes.   

Abstract

BACKGROUND: The CABG Patch trial compared prophylactic implantable cardiac-defibrillator (ICD) implantation with no antiarrhythmic therapy in coronary bypass surgery patients who had a left ventricular ejection fraction <0.36 and an abnormal signal-averaged ECG. There were 102 deaths among the 446 ICD group patients and 96 deaths among the 454 control group patients, a hazard ratio of 1.07 (P=0.63). The mechanisms of death were classified, and hypotheses were tested about the effects of ICD therapy on arrhythmic and nonarrhythmic cardiac deaths in the CABG Patch Trial and the Multicenter Automatic Defibrillator Implantation Trial (MADIT). METHODS AND
RESULTS: The 198 deaths in the trial were reviewed by an independent Events Committee and classified by the method of Hinkle and Thaler. Only 54 deaths (27%) occurred out of hospital; 145 deaths (73%) were witnessed. Seventy-nine (82%) of the 96 deaths in the control group and 76 (75%) of the 102 deaths in the ICD group were due to cardiac causes. Cumulative arrhythmic mortality at 42 months was 6.9% in the control group and 4.0% in the ICD group (P=0. 057). Cumulative nonarrhythmic cardiac mortality at 42 months was 12. 4% in the control group and 13.0% in the ICD group (P=0.275). Death due to pump failure was significantly associated with death >1 hour from the onset of symptoms, dyspnea within 7 days of death, and overt heart failure within 7 days of death.
CONCLUSIONS: In the CABG Patch Trial, ICD therapy reduced arrhythmic death 45% without significant effect on nonarrhythmic deaths. Because 71% of the deaths were nonarrhythmic, total mortality was not significantly reduced.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10086963     DOI: 10.1161/01.cir.99.11.1416

Source DB:  PubMed          Journal:  Circulation        ISSN: 0009-7322            Impact factor:   29.690


  32 in total

Review 1.  Prophylactic defibrillator implantation in patients with coronary artery disease.

Authors:  P A O'Callaghan
Journal:  Curr Cardiol Rep       Date:  2000-07       Impact factor: 2.931

Review 2.  Relationship of the implantable cardioverter defibrillator and chronic resynchronization therapy: the perfect marriage?

Authors:  David S Cannom; Morton Mower
Journal:  Ann Noninvasive Electrocardiol       Date:  2005-10       Impact factor: 1.468

3.  Sudden cardiac death unresponsive to implantable defibrillator therapy: an urgent target for clinicians, industry and government.

Authors:  Kelley P Anderson
Journal:  J Interv Card Electrophysiol       Date:  2005-11       Impact factor: 1.900

4.  Effective and efficient use of implantable defibrillators: sometimes it's over when it's over.

Authors:  Paul Dorian
Journal:  CMAJ       Date:  2009-03-17       Impact factor: 8.262

Review 5.  The timing of implantable cardioverter-defibrillator implantation in patients with heart failure.

Authors:  Nawaf S Al-Majed; Justin A Ezekowitz
Journal:  Curr Cardiol Rep       Date:  2012-06       Impact factor: 2.931

6.  Practice viewpoints: AICD, who and when?

Authors:  R J Sung; N-Y Chan
Journal:  Heart Asia       Date:  2009-01-01

Review 7.  A Questionable Indication For ICD Extraction After Successful VT Ablation.

Authors:  Luca Segreti; Andrea Di Cori; Giulio Zucchelli; Ezio Soldati; Giovanni Coluccia; Stefano Viani; Luca Paperini; Maria Grazia Bongiorni
Journal:  J Atr Fibrillation       Date:  2015-04-30

Review 8.  Who should receive an implantable cardioverter-defibrillator after myocardial infarction?

Authors:  Stavros Mountantonakis; Mathew D Hutchinson
Journal:  Curr Heart Fail Rep       Date:  2009-12

9.  Prevalence and mortality of patients with myocardial infarction and reduced left ventricular ejection fraction in a defined community: relation to the second multicenter automatic defibrillator implantation trial.

Authors:  Param P Sharma; Robert T Greenlee; Kelley P Anderson; Po-Huang Chyou; Hector J Osorio; Peter N Smith; John H Hayes; Humberto Vidaillet
Journal:  J Interv Card Electrophysiol       Date:  2007-09-06       Impact factor: 1.900

10.  Comparison of linear-stochastic and nonlinear-deterministic algorithms in the analysis of 15-minute clinical ECGs to predict risk of arrhythmic death.

Authors:  James E Skinner; Michael Meyer; Brian A Nester; Una Geary; Pamela Taggart; Antoinette Mangione; George Ramalanjaona; Carol Terregino; William C Dalsey
Journal:  Ther Clin Risk Manag       Date:  2009-08-20       Impact factor: 2.423

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.