UNLABELLED: Coregistration of images from a single subject, acquired by different modalities, is important in clinical diagnosis, surgery and therapy planning. The purpose of this study was to evaluate, using a physical torso phantom, a novel, fully automated method for three-dimensional image registration of CT and SPECT, using radionuclide transmission (RNT) attenuation maps.
METHODS: We obtained CT scans and SPECT scans paired with RNT maps of an anthropomorphic cardiac phantom. RNT attenuation maps were acquired using an uncollimated 99mTc-filled flood source. RNT and SPECT scans were acquired in the same spatial orientation (usual clinical practice in nonuniform attenuation correction). In addition, CT attenuation maps (CTMAPs) for 99mTc SPECT were generated from CT by linear energy scaling. RNT maps were registered to CT and CTMAPs by iterative simplex minimization of count difference and uniformity index (sum of RNT map intensity variances corresponding to each intensity level in the CT volume). In each iteration, three shifts and three angles were adjusted. To register SPECT to CT, we applied the RNT transformation parameters to SPECT.
RESULTS: RNT maps could be registered to CT and CTMAP images using both criteria. The average three-dimensional distance between landmark and automated registration was 2.5 +/- 1.2 mm for count difference and 3.3 +/- 1.3 mm for uniformity index. The three-dimensional reproducibility errors were 1.2 +/- 0.7 mm for count difference, 2.1 +/- 0.5 mm for uniformity index and 2.3 +/- 1.0 mm for manual marker registration. The minimization of uniformity index was robust when up to 50% CT or RNT slices were missing and was not affected significantly (<2 mm) by realistic variation in CT values (+/- 12 Hounsfield units).
CONCLUSION: In addition to typical use in nonuniform attenuation correction, RNT maps can be used for fully automated three-dimensional registration of SPECT to CT. Such registration is not affected by features and quality of SPECT images and avoids difficulties associated with fiducial markers. Our method can be applied to SPECT-CT registration of various organs, such as brain, heart, lungs, breasts and abdomen, including oncological scans.

Mesh:

Year:  1999        PMID: 10086710

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  8 in total

1.  Registration accuracy of 153Gd transmission images of the brain.

Authors:  F Jacobs; M Koole; I Goethals; C Van de Wiele; H Ham; R Dierckx
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-07-06       Impact factor: 9.236

2.  Automated quality control of emission-transmission misalignment for attenuation correction in myocardial perfusion imaging with SPECT-CT systems.

Authors:  Ji Chen; Serpil F Caputlu-Wilson; Hongcheng Shi; James R Galt; Tracy L Faber; Ernest V Garcia
Journal:  J Nucl Cardiol       Date:  2006 Jan-Feb       Impact factor: 5.952

Review 3.  Multimodality image registration with software: state-of-the-art.

Authors:  Piotr J Slomka; Richard P Baum
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

4.  Image coregistration: quantitative processing framework for the assessment of brain lesions.

Authors:  Hannu Huhdanpaa; Darryl H Hwang; Gregory G Gasparian; Michael T Booker; Yong Cen; Alexander Lerner; Orest B Boyko; John L Go; Paul E Kim; Anandh Rajamohan; Meng Law; Mark S Shiroishi
Journal:  J Digit Imaging       Date:  2014-06       Impact factor: 4.056

5.  A framework of whole heart extracellular volume fraction estimation for low-dose cardiac CT images.

Authors:  Xinjian Chen; Marcelo S Nacif; Songtao Liu; Christopher Sibley; Ronald M Summers; David A Bluemke; Jianhua Yao
Journal:  IEEE Trans Inf Technol Biomed       Date:  2012-06-12

6.  Assessment of regional lung functional impairment with co-registered respiratory-gated ventilation/perfusion SPET-CT images: initial experiences.

Authors:  Kazuyoshi Suga; Kawakami Yasuhiko; Mohammed Zaki; Tomio Yamashita; Aska Seto; Tsuneo Matsumoto; Naofumi Matsunaga
Journal:  Eur J Nucl Med Mol Imaging       Date:  2004-02       Impact factor: 9.236

7.  Automatic PET-CT image registration method based on mutual information and genetic algorithms.

Authors:  Martina Marinelli; Vincenzo Positano; Francesco Tucci; Danilo Neglia; Luigi Landini
Journal:  ScientificWorldJournal       Date:  2012-04-19

8.  A geometrical approach for automatic shape restoration of the left ventricle.

Authors:  May-Ling Tan; Yi Su; Chi-Wan Lim; Senthil Kumar Selvaraj; Liang Zhong; Ru-San Tan
Journal:  PLoS One       Date:  2013-07-19       Impact factor: 3.240