Literature DB >> 10086512

Determinants of plasma fibrin D-dimer sensitivity for acute pulmonary embolism as defined by pulmonary angiography.

J A Heit1, T A Minor, J C Andrews, D R Larson, H Li, W L Nichols.   

Abstract

BACKGROUND: The reported operating characteristics of the plasma fibrin D-dimer level for the diagnosis of acute pulmonary embolism vary widely.
OBJECTIVE: To determine the sensitivity, specificity, predictive value, and clinical utility of the D-dimer for the diagnosis of pulmonary embolism, and to describe the effect of D-dimer assay method (enzyme-linked immunosorbent assay [ELISA], latex agglutination, membrane ELISA) and discriminate level, patient location at onset, comorbid disease, duration and intensity of concurrent heparin administration, and duration of symptoms on these operating characteristics.
DESIGN: Prospective laboratory investigation.
SETTING: Community and tertiary care teaching hospital. PATIENTS: Consecutive patients with suspected acute pulmonary embolism referred for pulmonary angiography from April 1993 through March 1996. MEASUREMENTS: Baseline characteristics, the duration and intensity of heparin anticoagulation, the time interval between symptom onset and plasma D-dimer testing, pulmonary angiography, and the D-dimer level on the day of pulmonary angiography.
RESULTS: Of 105 consenting patients, 33 (31%) had a positive pulmonary angiogram. The D-dimer sensitivity/ negative predictive value for the ELISA, latex agglutination (American Bioproducts Co/Diagnostica Stago and Biopool International), and membrane ELISA were 100%/100%, 94%/94%, 100%/100%, and 97%/96%, respectively, at a discriminate level of 250 microg/L or less. The clinical utility, defined as the prevalence of a negative test, ranged from 17% to 33%. D-dimer sensitivity was unaffected by patient location at onset, comorbid disease, or heparin therapy but was inversely related to the duration of symptoms.
CONCLUSIONS: The sensitivity of the plasma fibrin D-dimer for the diagnosis of pulmonary embolism depends on the assay method, the assay-specific discriminate level, and the duration of symptoms. At the appropriate discriminate level, the plasma D-dimer is a sensitive but nonspecific test for the diagnosis of pulmonary embolism.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10086512     DOI: 10.5858/1999-123-0235-DOPFDD

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  7 in total

Review 1.  Role of fibrin D-dimer testing in emergency medicine.

Authors:  A Wakai; A Gleeson; D Winter
Journal:  Emerg Med J       Date:  2003-07       Impact factor: 2.740

Review 2.  D-dimer testing: advantages and limitations in emergency medicine for managing acute venous thromboembolism.

Authors:  Sergio Siragusa
Journal:  Intern Emerg Med       Date:  2006       Impact factor: 3.397

Review 3.  Systematic review and meta-analysis of strategies for the diagnosis of suspected pulmonary embolism.

Authors:  Pierre-Marie Roy; Isabelle Colombet; Pierre Durieux; Gilles Chatellier; Hervé Sors; Guy Meyer
Journal:  BMJ       Date:  2005-07-30

4.  D-dimer in the diagnostic workup of suspected pulmonary thrombo-embolism at high altitude.

Authors:  Kr Rathi; Vikram Uppal; Nm Bewal; Debraj Sen; Anurag Khanna
Journal:  Med J Armed Forces India       Date:  2012-04-21

5.  The diagnostic yield of D-Dimer in relation to time from symptom onset in patients evaluated for venous thromboembolism in the emergency medicine department.

Authors:  Yelena Goldin; Oren Pasvolsky; Ori Rogowski; Itzhak Shapira; Arie Steinvil; Pinchas Halpern; Jack Serov; Varda Deutsch; Galit Aviram; Shlomo Berliner
Journal:  J Thromb Thrombolysis       Date:  2011-01       Impact factor: 2.300

6.  Clinical usefulness and safety of an age-adjusted D-dimer cutoff levels to exclude pulmonary embolism: a retrospective analysis.

Authors:  Julio Flores; Jaime García de Tena; Javier Galipienzo; Ángel García-Avello; Esteban Pérez-Rodríguez; José Ignacio Tortuero; Concepción Álvarez; Antonio Ruíz; Ignacio Arribas
Journal:  Intern Emerg Med       Date:  2015-09-07       Impact factor: 3.397

Review 7.  Effectiveness of d-dimer as a screening test for venous thromboembolism: an update.

Authors:  Swaroopa Pulivarthi; Murali Krishna Gurram
Journal:  N Am J Med Sci       Date:  2014-10
  7 in total