Literature DB >> 10080419

Clinical utility of negative contrast intravascular ultrasound to evaluate plaque morphology before and after coronary interventions.

J Honye1, S Saito, T Takayama, J Yajima, T Shimizu, M Chiku, T Mizumura, Y Takaiwa, K Horiuchi, M Moriuchi, K Komaki, Y Ozawa, K Kanmatsuse, J M Tobis.   

Abstract

Although intravascular ultrasound (IVUS) is used for evaluation of plaque volume and lumen size as well as detection of vessel wall structures after catheter-based interventions, differentiation between the lumen and plaque structures can be difficult. This study attempted to evaluate the efficacy of negative contrast IVUS imaging for assessment of vessel wall morphology after coronary interventions. IVUS studies were performed in 67 lesions in 66 patients before and after coronary interventions. After the baseline ultrasound imaging run, warm 5% glucose solution was injected manually through the guiding catheter into the coronary artery to washout blood from the lumen to avoid speckled reflections from red blood cells (negative contrast). Quantitative measurements were obtained and plaque morphology was assessed for the presence and extent of medial dissections and intimal flaps. There was no difference in each quantitative parameter between baseline images and negative contrast images. The vessel wall boundary was clearly delineated from the lumen, which was defined as effective negative contrast in 51 of 67 lesions (76%). The baseline images revealed plaque dissection in 9 lesions (18%) and an intimal flap in 13 lesions (25%). In addition, 4 dissections (8%) and 16 intimal flaps (31%) were visualized during the infusion of negative contrast. Additional treatment was performed in 4 lesions (8%) based on the images with negative contrast. Negative contrast IVUS was more sensitive in demonstrating a plaque fracture than were baseline images. This method is useful for enhancing the diagnostic capability of IVUS imaging and may influence the decision-making process during interventional procedures.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10080419     DOI: 10.1016/s0002-9149(98)00971-0

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  4 in total

1.  Combining Subharmonic and Ultraharmonic Modes for Intravascular Ultrasound Imaging: A Preliminary Evaluation.

Authors:  Himanshu Shekhar; Jeffrey S Rowan; Marvin M Doyley
Journal:  Ultrasound Med Biol       Date:  2017-08-26       Impact factor: 2.998

2.  Lesion characteristics of acute myocardial infarction: an investigation with intravascular ultrasound.

Authors:  D Fukuda; T Kawarabayashi; A Tanaka; Y Nishibori; H Taguchi; Y Nishida; K Shimada; J Yoshikawa
Journal:  Heart       Date:  2001-04       Impact factor: 5.994

Review 3.  Intracoronary Imaging in the Detection of Vulnerable Plaques.

Authors:  Jonathan A Batty; Shristy Subba; Peter Luke; Li Wing Chi Gigi; Hannah Sinclair; Vijay Kunadian
Journal:  Curr Cardiol Rep       Date:  2016-03       Impact factor: 2.931

Review 4.  Clinical expert consensus document on intravascular ultrasound from the Japanese Association of Cardiovascular Intervention and Therapeutics (2021).

Authors:  Yuichi Saito; Yoshio Kobayashi; Kenichi Fujii; Shinjo Sonoda; Kenichi Tsujita; Kiyoshi Hibi; Yoshihiro Morino; Hiroyuki Okura; Yuji Ikari; Junko Honye
Journal:  Cardiovasc Interv Ther       Date:  2021-11-12
  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.