Literature DB >> 10080098

Mechanical properties of collagen fascicles from the rabbit patellar tendon.

E Yamamoto1, K Hayashi, N Yamamoto.   

Abstract

Tensile and viscoelastic properties of collagen fascicles of approximately 300 microns in diameter, which were obtained from rabbit patellar tendons, were studied using a newly designed micro-tensile tester. Their cross-sectional areas were determined with a video dimension analyzer combined with a CCD camera and a low magnification microscope. There were no statistically significant differences in tensile properties among the fascicles obtained from six medial-to-lateral locations of the patellar tendon. Tangent modulus, tensile strength, and strain at failure of the fascicles determined at about 1.5 percent/s strain rate were 216 +/- 68 MPa, 17.2 +/- 4.1 MPa, and 10.9 +/- 1.6 percent (mean +/- S.D.), respectively. These properties were much different from those of bulk patellar tendons; for example, the tensile strength and strain at failure of these fascicles were 42 percent and 179 percent of those of bulk tendons, respectively. Tangent modulus and tensile strength of collagen fascicles determined at 1 percent/s strain rate were 35 percent larger than those at 0.01 percent/s. The strain at failure was independent of strain rate. Relaxation tests showed that the reduction of stress was approximately 25 percent at 300 seconds. These stress relaxation behavior and strain rate effects of collagen fascicles differed greatly from those of bulk tendons. The differences in tensile and viscoelastic properties between fascicles and bulk tendons may be attributable to ground substances, mechanical interaction between fascicles, and the difference of crimp structure of collagen fibrils.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10080098     DOI: 10.1115/1.2798033

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  17 in total

1.  Tension tests on mammalian collagen fibrils.

Authors:  Yehe Liu; Roberto Ballarini; Steven J Eppell
Journal:  Interface Focus       Date:  2016-02-06       Impact factor: 3.906

2.  Viscoelastic properties of isolated collagen fibrils.

Authors:  Zhilei Liu Shen; Harold Kahn; Roberto Ballarini; Steven J Eppell
Journal:  Biophys J       Date:  2011-06-22       Impact factor: 4.033

3.  A mechanistic study for strain rate sensitivity of rabbit patellar tendon.

Authors:  John Clemmer; Jun Liao; Debbie Davis; Mark F Horstemeyer; Lakiesha N Williams
Journal:  J Biomech       Date:  2010-08-03       Impact factor: 2.712

4.  Multiscale mechanics of the cervical facet capsular ligament, with particular emphasis on anomalous fiber realignment prior to tissue failure.

Authors:  Sijia Zhang; Vahhab Zarei; Beth A Winkelstein; Victor H Barocas
Journal:  Biomech Model Mechanobiol       Date:  2017-08-18

5.  Tensile properties of human collagen fibrils and fascicles are insensitive to environmental salts.

Authors:  René B Svensson; Tue Hassenkam; Colin A Grant; S Peter Magnusson
Journal:  Biophys J       Date:  2010-12-15       Impact factor: 4.033

Review 6.  Pathogenesis of tendinopathies: inflammation or degeneration?

Authors:  Michele Abate; Karin Gravare Silbernagel; Carl Siljeholm; Angelo Di Iorio; Daniele De Amicis; Vincenzo Salini; Suzanne Werner; Roberto Paganelli
Journal:  Arthritis Res Ther       Date:  2009-06-30       Impact factor: 5.156

7.  Tendon fascicles exhibit a linear correlation between Poisson's ratio and force during uniaxial stress relaxation.

Authors:  Shawn P Reese; Jeffrey A Weiss
Journal:  J Biomech Eng       Date:  2013-03-01       Impact factor: 2.097

8.  Ex vivo supplementation of TGF-beta1 enhances the fibrous tissue regeneration effect of synovium-derived fibroblast transplantation in a tendon defect: a biomechanical study.

Authors:  Shoichi Okamoto; Harukazu Tohyama; Eiji Kondo; Yuko Anaguchi; Shin Onodera; Kozaburo Hayashi; Kazunori Yasuda
Journal:  Knee Surg Sports Traumatol Arthrosc       Date:  2007-09-06       Impact factor: 4.342

9.  Micromechanical model of a surrogate for collagenous soft tissues: development, validation and analysis of mesoscale size effects.

Authors:  Shawn P Reese; Benjamin J Ellis; Jeffrey A Weiss
Journal:  Biomech Model Mechanobiol       Date:  2013-02-12

10.  Modeling of the transient responses of the vocal fold lamina propria.

Authors:  Kai Zhang; Thomas Siegmund; Roger W Chan
Journal:  J Mech Behav Biomed Mater       Date:  2009-01
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.