Literature DB >> 10079760

Detection of peptides by precolumn derivatization with biuret reagent and preconcentration on capillary liquid chromatography columns with electrochemical detection.

H Shen1, S R Witowski, B W Boyd, R T Kennedy.   

Abstract

The separation and detection of biuret complexes of neuropeptides by capillary liquid chromatography with electrochemical detection was explored. Capillaries of 25-micron inner diameter packed with base-resistant, polymer-based reversed-phase particles were used for separation, and C-fiber electrodes were used for detection. Detection at the C-fiber electrode was found to have some differences in relative sensitivity for peptides compared to glassy carbon electrodes used previously. On-column preconcentration of preformed complexes allowed up to 1-microL samples to be injected with minimal band broadening resulting in a 100-fold improvement in concentration detection limit with no effect on mass detection limit. Concentration detection limits ranged from 5 to 59 pM, depending upon the peptide, corresponding to 5-59 amol injected. The low concentration detection limit was possible because of minimal baseline disturbances, minimal formation of unwanted products, and high efficiency of complex formation associated with biuret derivatization. The method was applied to determination of vasopressin and bradykinin in dialysates collected with 5-min sampling frequency from the rat supraoptic nucleus.

Entities:  

Mesh:

Substances:

Year:  1999        PMID: 10079760     DOI: 10.1021/ac9809837

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  6 in total

1.  Techniques for neuropeptide determination.

Authors:  Mats Sandberg; Stephen G Weber
Journal:  Trends Analyt Chem       Date:  2003-09       Impact factor: 12.296

2.  Evaluation of an on-capillary copper complexation methodology for the investigation of in vitro metabolism of dynorphin A 1-17.

Authors:  Courtney D Kuhnline; Susan M Lunte
Journal:  J Sep Sci       Date:  2010-08       Impact factor: 3.645

3.  Electrochemical and optical detectors for capillary and chip separations.

Authors:  Xiaomi Xu; Ling Li; Stephen G Weber
Journal:  Trends Analyt Chem       Date:  2007-01       Impact factor: 12.296

4.  The Rotating Ring-Disk Electrochemistry of the Copper(II) Complex of Thyrotropin-releasing Hormone.

Authors:  Rong Meng; Stephen G Weber
Journal:  J Electroanal Chem (Lausanne)       Date:  2007-02-15       Impact factor: 4.464

5.  Analysis of the performance of a flow reactor for use with microcolumn HPLC.

Authors:  Amy T Beisler; Eskil Sahlin; Kathleen E Schaefer; Stephen G Weber
Journal:  Anal Chem       Date:  2004-02-01       Impact factor: 6.986

6.  Practical aspects of in vivo detection of neuropeptides by microdialysis coupled off-line to capillary LC with multistage MS.

Authors:  Qiang Li; Jon-Kar Zubieta; Robert T Kennedy
Journal:  Anal Chem       Date:  2009-03-15       Impact factor: 6.986

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.